Primera Technology LX900 Benutzerhandbuch

Seite von 62
Label Stock
11
C. ADJUSTING THE LABEL STOCK 
TOF
 (TOP OF FORM) 
SENSOR
If you are using label stock other than standard square / 
rectangular diecut labels such as circular die-cut labels or
through-hole stock use the instructions below to adjust the
position of the label stock sensor. The sensor can be adjusted
using the slide bar on the inside of the printer. Below the slide
bar is a measurement which represents the distance between
the edge of the label stock and the sensor. Measure the 
distance from the edge of the label stock to the correct position
on the stock. Set the sensor to this measurement.
Important Note: You must adjust the Stock Sensor before loading non-
standard label stock.
Circular Labels
If you are using Circular Labels you must adjust the Stock 
sensor to correspond with the very top of the label where the
circles are closest together. If the sensor is too far to the right or
the left the printer will still sense the label but the image may
be offset downward because the printer will start printing at
the wrong position. If you are using stock that has multiple
labels across make sure the sensor corresponds to a place on
the stock that has a label and not a vertical gap.
0.5
1.0
1.5
2.0
12.7
25.4
38.1
50.8
mm
   in.
Label Stock Sensor Slide
LX900.qxd  1/14/2010  12:41 PM  Page 11
TOC
INDEX
TOC
TOC
INDEX