 CAUTION 
When replacing the dispensing chute, ensure that the door hinge screws are to the right as you face 
the unit. 
 
3.2 Operator 
Troubleshooting
 
 
The operator troubleshooting guides that follow are intended to help operators resolve routine problems that 
may be encountered during operation of the unit. 
 
PROBLEM 
Probable Causes 
Corrective Action 
A. 
ON/OFF rocker switch is in OFF 
position. 
A. 
Place rocker switch in the ON 
position. 
B. 
Unit is not plugged in. 
B. 
Plug unit in. 
C. 
Main circuit breaker is tripped. 
C. 
Reset circuit breaker. 
UNIT WILL NOT 
POWER UP or 
NOTHING HAPPENS 
WHEN “RUN” MODE 
IS SELECTED.  If the problem is not corrected by one of the above actions, call FASC. 
A. 
Dispensing chute is not properly 
positioned on the load cell arms. 
A. 
Reposition dispensing chute so that 
is firmly seated on the load cell 
arms.  Turn the unit OFF then back 
ON using the ON/OFF rocker 
switch.  Press the RUN switch 
RUN SWITCH 
INDICATOR AND 
PROGRAM SWITCH 
INDICATOR ARE 
FLASHING.  Simultaneous flashing of the run switch indicator and program switch indicator 
signals that the unit is not properly zeroed.  If the problem is not corrected by the 
above action, call FASC. 
A. 
Dispensing chute is full. 
A. 
If the dispense chute has been 
loaded but not dispensed, nothing 
will happen until the batch has been 
dispensed, except when the batch 
weight is increased. Insert a basket 
into the dispensing well to dispense 
batch. 
B. 
Unit is not in RUN mode. 
B. 
Press RUN switch once. 
NOTHING HAPPENS 
WHEN A BATCH 
SIZE SELECTOR IS 
PRESSED. 
If one of the above actions did not correct the problem, call FASC. 
A. 
The load cell may not have been 
satisfied within 30 seconds, normally 
because the hopper is empty or the 
fries have “bridged”. 
A. 
Check the hopper to verify that the 
deflector is properly positioned.  If 
there are fries in the hopper, verify 
that there is no bridging.  If the 
hopper is empty, reload the hopper.  
Press the PROGRAM switch once 
to place the unit back into opera-
tion. 
DISPENSE DOOR 
DOES NOT OPEN 
WHEN BASKET IS 
INSERTED. 
If the above action did not correct the problem, call FASC. 
ERRATIC BATCH 
WEIGHTS ARE 
BEING DISPENSED. 
A. 
If the erratic batch weights are 
occurring only occasionally, the 
probable cause is bumping, jarring, 
and/or unusual vibration (such as 
caused by inserting a basket with 
undue force, the slamming of a freezer 
door, or the passing of a nearby train).
A. 
Exercise care when working around 
the unit to avoid bumping or jarring 
it while it is in operation.  Ensuring 
that the unit is not touching 
adjacent walls, and placing the unit 
on a rubber mat will reduce the 
effect of environmental vibrations.