3-3 
PROBLEM 
Probable Causes 
Corrective Action 
B. 
If the erratic batch weights are 
occurring consistently, the probable 
cause is a misaligned component. 
B. 
Verify that the dispensing chute is 
properly positioned on the load cell 
arms, that the deflector is properly 
positioned in the hopper, and that 
the hopper is fully seated behind 
the locking rim on the cradle 
assembly. 
Continued from 
previous page. 
 
If one of the above actions does not correct the problem, there may be a problem 
with the programmed weight settings or the load cell.  Call FASC. 
A. 
Unit was not in STANDBY mode 
when attempt was made to enter 
CLEAN mode. 
A. 
The CLEAN mode can only be 
selected when the unit is in the 
STANDBY mode. 
 
Press the RUN Switch once to 
place the unit in the STANDBY 
mode, and then press the CLEAN 
Switch. 
UNIT WILL NOT GO 
INTO CLEAN MODE. 
If the above action did not correct the problem, call FASC.