Hoshizaki DT-400BAH-OS Benutzerhandbuch

Seite von 21
10
G. Final Checklist 
1) Is the icemaker level?
2) Is the icemaker in a site where the ambient temperature is within +45°F to +100°F 
(+7°C to +38°C) and the water temperature is within +45°F to +90°F (+7°C to +32°C) 
all year around?
3) Is there at least a 6" (15 cm) clearance behind and above the icemaker for maintenance 
or service?
4) Have the shipping carton, tape, and packing material been removed from the 
icemaker?
5) Are all components, fasteners, and thumbscrews securely in place? 
6) Have all electrical and piping connections been made?
7) Has the power supply voltage been checked or tested against the nameplate rating? 
Has a proper ground been installed to the icemaker? 
8) Are the water supply line shut-off valve and drain valve installed? Has the water 
supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of 
113 PSIG?
9) Are the compressor hold-down bolts snug? Have the refrigerant lines been checked to 
make sure they do not rub or touch other lines or surfaces? 
10) Has the end user been given the instruction manual, and instructed on how to operate 
the icemaker and the importance of the recommended periodic maintenance?
11) Has the end user been given the name and telephone number of an authorized service 
agent?
12) Has the warranty card been filled out and forwarded to the factory for warranty 
registration?