thermal eXpansion
Water  supply  systems  may,  because  of  such  events  as  high  line 
pressure, frequent cut-offs, the effects of water hammer among others, 
have installed devices such as pressure reducing valves, check valves, 
back flow preventers, etc. to control these types of problems. When 
these devices are not equipped with an internal by-pass, and no other 
measures are taken, the devices cause the water system to be closed.  
As water is heated, it expands (thermal expansion) and closed systems 
do not allow for the expansion of heated water.
The water within the water heater tank expands as it is heated and 
increases the pressure of the water system.  If the relieving point of 
the water heater’s temperature-pressure relief valve is reached, the 
valve will relieve the excess pressure. 
the temperature-pressure 
relief valve is not intended for the constant relief of thermal 
expansion. This is an unacceptable condition and must be corrected. 
It is recommended that any devices installed which could create a 
closed system have a by-pass and/or the system have an expansion 
tank or device to relieve the pressure built by thermal expansion in 
the water system.  Expansion tanks are available for ordering through 
a local plumbing contractor.  Contact the local water heater supplier 
or service agency for assistance in controlling these situations.
stranGe sounds
Possible noises due to expansion and contraction of some metal 
parts during periods of heat-up and cool-down do not necessarily 
represent harmful or dangerous conditions.
operational conditions
water odor
In each water heater there is installed at least one anode rod (see 
parts sections) for corrosion protection of the tank. Certain water 
conditions  will  cause  a  reaction  between  this  rod  and  the  water.  
The most common complaint associated with the anode rod is one 
of a “rotten egg smell” in the hot water. This odor is derived from 
hydrogen sulfide gas dissolved in the water. The smell is the result 
of four factors which must all be present for the odor to develop:
A.  A concentration of sulfate in the supply water.
B.  Little or no dissolved oxygen in the water.
C.  A sulfate reducing bacteria which has accumulated within the 
water heater (this harmless bacteria is nontoxic to humans).
D.  An excess of active hydrogen in the tank. This is caused by the 
corrosion protective action of the anode.
Smelly water may be eliminated or reduced in some water heater 
models by replacing the anode(s) with one of less active material, 
and then chlorinating the water heater tank and all hot water lines.  
Contact the local water heater supplier or service agency for further 
information concerning an Anode Replacement Kit and this chlorination 
treatment. If the smelly water persists after the anode replacement and 
chlorination treatment, we can only suggest that chlorination or aeration 
of the water supply be considered to eliminate the water problem.
do not remove the anode leaving the tank unprotected. By doing 
so, all warranty on the water heater tank is voided.
“air” in hot water faucets
HYDROGEN GAS: Hydrogen gas can be produced in a hot water 
system that has not been used for a long period of time (generally 
two weeks or more).  Hydrogen gas is extremely flammable and 
explosive.  To prevent the possibility of injury under these conditions, 
we recommend the hot water faucet, located farthest away be opened 
for  several  minutes  before  any  electrical  appliances  which  are 
connected to the hot water system are used (such as a dishwasher 
or washing machine).  If hydrogen gas is present, there will probably 
be an unusual sound similar to air escaping through the pipe as the 
hot water faucet is opened.  There must be no smoking or open 
flame near the faucet at the time it is open.
hiGh water temperature shut off sYstem
A  non-adjustable  high  temperature  limit  control  operates  before 
steam temperatures are reached. The high limit switch must be reset 
manually when it operates. BECAUSE THE HIGH LIMIT OPERATES 
ONLY  WHEN  ABNORMALLY  HIGH  WATER  TEMPERATURES 
ARE  PRESENT,  IT  IS  IMPORTANT  THAT  A  QUALIFIED 
SERVICE  AGENT  BE  CONTACTED  TO  DETERMINE 
THE  REASON  FOR  OPERATION  BEFORE  RESETTING .
•  Turn  off  and  unplug  the  water  heater.  Do  not  attempt  to  reset 
thermostat with power on.
•  Remove  the  front  panel,  see  “Removing  Front  Panel”  in  the 
Periodic Maintenance section.
•  Remove the insulation to expose the reset button.
•  Reset the high limit by pushing in the red button.
•  Replace the insulation so that it completely covers the thermostat 
and element.
•  Replace the front panel.
•  Plug in and turn on the water heater.
for Your information