5
3.  Using a Philips screwdriver, unscrew the bottom screw securing 
the outer door, see Figure 8. 
4.  Lift up and remove front panel.
fiGure 8.
thermostat removal / replacement
REMOVAL
1.  Turn off and unplug the water heater from the electrical outlet.
2.  Remove  the  front  panel,  see  the  “REMOVING THE  FRONT 
PANEL” section in this manual.  Remove the insulation pad.
3.  Using a 7mm wrench, loosen the nuts securing the high limit switch 
to the tank enough to rotate the switch 90° counterclockwise and 
slide it out from beneath the bracket. It is not necessary to remove 
the nuts completely.
4.  Remove the 3 wires (white, brown, and green/yellow) from the 
thermostat at the spade connections, carefully taking note of the 
original location of each wire.
5.  Unscrew the 2 screws securing the thermostat to the front panel 
and remove thermostat.
fiGure 9.
REPLACEMENT 
1.  Place the new thermostat against the front panel and secure 
it with the two screws.
2.  Reattach the wires at the spade connections, taking care to 
place  them  in  their  original  locations.  Be  sure  to  push  the 
connector completely onto the spade terminals.
3.  Secure the temperature sensor to the tank by tightening the 
nuts.  Be  sure  the  sensor  is  firmly  in  contact  with  the  tank 
surface.
4.  Replace the insulation block and the front panel.
element cleaninG / replacement
To remove the element from the tank in order to clean or replace it:
.  Turn off and unplug the water heater from the electrical outlet 
and follow “DRAINING INSTRUCTIONS.”
2.  Remove  the  front  panel,  see  the  “REMOVING THE  FRONT 
PANEL” section in this manual.  Remove the insulation pad.
3.  Remove  the  two  screws  from  the  mounting  bracket,  see  Figure 
10, being careful not to drop the screws into the unit, as they will 
be difficult to retrieve. Remove bracket and set screws aside.
4.  Remove the two spade connectors from the element. 
5.  Using a 10mm wrench, remove the four nuts around the element 
flange. Set nuts and lockwashers aside. 
6.  Lift element up to clear the four mounting bolts, rotate 15° clockwise, 
and lift out.
7.  Discard  the  old  gasket  and  clean  the  area  around  the  element 
opening. Remove any sediment from or around the element opening 
and inside the tank.
8.  If you are cleaning the element you have removed, do so by 
scraping or soaking in vinegar or a deliming solution.
note: replacement elements must (1) be the same voltage 
and (2) no greater wattage than listed on the model rating plate 
affixed to the water heater.
9.  A new gasket must be used in all cases to prevent a possible 
water leak. Place new element gasket in the element opening 
over the four element bolts, orienting the gasket bulge facing 
water side.
10. Insert the curved part of the element, rotate 20° clockwise, and 
continue to insert the element, being sure that the four bolts fit into 
the element flange.
11. Replace the four lockwashers and 10mm nuts. Tighten until snug. 
DO NOT OVERTIGHTEN. 