not cause any property damage, as the water may be extremely hot, 
see Figure 7.
fiGure  7.
If after manually operating the valve, it fails to completely reset and 
continues to release water, immediately close the cold water inlet 
to the water heater, follow the draining instructions, and replace the 
temperature-pressure relief valve with a new one.
If  the  temperature-pressure  relief  valve  on  the  appliance  weeps 
or discharges periodically, this may be due to thermal expansion.  
You may have a check valve installed in the water line or a water 
meter  with  a  check  valve.    Consult  your  local  water  supplier  or 
service agency for  further information.  Do not plug or remove the 
temperature-pressure relief valve.
draininG
The  water  heater  should  be  drained  if  being  shut  down  during 
freezing  temperatures.   Also  periodic  draining  and  cleaning  of 
sediment from the tank may be necessary.
1.  Turn off and unplug the water heater from the electrical outlet.
2.  CLOSE the cold water inlet valve to the water heater.
3.  OPEN a nearby hot water faucet and leave open to allow for 
draining.
4.  Disconnect water connections. Remove unit from wall. UNIT WILL 
BE HEAVY. Turn unit upside down and drain unit into a suitable 
drain or receptacle.
removinG the  front panel
1.  Turn off and unplug the water heater from the electrical outlet 
and follow “DRAINING INSTRUCTIONS.”
2.  Remove the temperature knob by pulling straight out.
anode rod inspection
The anode rod is used to protect the tank from corrosion. Most hot 
water tanks are equipped with an anode rod. The submerged rod 
sacrifices itself to protect the tank. Instead of corroding the tank, water 
ions attack and eat away the anode rod. This does not affect the 
water’s taste or color. The rod must be maintained to keep the tank 
in operating condition.
NOTE: The use of a water softener may decrease the life of the water 
heater tank.
Anode  deterioration  depends  on  water  conductivity,  not 
necessarily  water  condition. A  corroded  or  pitted  anode  rod 
indicates high water conductivity and should be checked and/or 
replaced  more  often  than    an  anode  rod  that  appears  to  be 
intact.  Replacement  of  a  depleted  anode  rod  can  extend  the 
life of your water heater. Inspection should be conducted by a 
qualified technician, and at a minimum should be checked every 
three years. The anode rod in this unit is attached to the element 
flange. For removal instructions, see “ELEMENT CLEANING / 
REPLACEMENT.” 
Typical  (but  not  all)  signs  of  a  depleted  anode  rod  are  as 
follows:
•  The majority of the rods diameter is less than 3/8”
•  Significant sections of the support wire (approximately 1/3 or more  
  of the anode rod’s length) are visible.
If the anode rod shows signs of either or both it should be replaced. 
NOTE: Whether re-installing or replacing  the anode rod, check 
for any leaks and immediately correct if found.
temperature-pressure relief valve operation
                         
                      
The temperature-pressure relief valve must be manually operated 
at least once a year.
When checking the temperature-pressure relief valve operation, make 
sure that (1) no one is in front of or around the outlet of the temperature-
pressure relief valve discharge line, and (2) that the water discharge will 
periodic maintenance