A.O. Smith AOSRE50400 Benutzerhandbuch

Seite von 24
7
leaKaGe checKpoints
Read this manual first.  Make sure the electrical power supply has 
been turned “OFF” before checking the tank for leakage.
 *A.  Condensation and dripping may be seen on pipes if the water 
temperature is low in humid weather or pipe connections may 
be leaking.
  B.  Small amounts of water from temperature-pressure relief valve 
may be due to thermal expansion or high water pressure in your 
area. If the valve is not piped to an open drain the released 
water could  be mistaken for a leaking  heater, see “Thermal 
Expansion” section.
 *C.  The temperature-pressure relief valve may be leaking at the 
tank fitting.
  D.  Water on the side of the tank may be condensation due to the 
panel or insulation not being in place.
   
 *E.  Water in the water heater bottom or on the floor may be from 
condensation, loose connections, or the relief valve.  DO NOT 
replace the water heater until a full inspection of all possible 
water sources is made and necessary corrective steps taken.
    Leakage from other appliances, water lines, or ground seepage 
should also be checked.
  *    To  check  where  threaded  portion  enters  tank,  insert  cotton 
swab between jacket opening and fitting.  If cotton is wet, follow 
“Draining” instructions in the “Periodic Maintenance” section 
and then remove fitting.  Put pipe dope or teflon tape on the 
threads and replace.  Then follow  “Filling the Water Heater” 
instructions in the “Installing the New Water Heater” section.
    
Key no.  part description
fiGure  12.