A.O. Smith AOSRE50400 Benutzerhandbuch

Seite von 24
16
water inlet and outlet, open the nearest hot water tap and follow 
filling instructions.
Never use this water heater unless it is completely full of water. To 
prevent damage to the tank and heating element, the tank must be 
filled with water. Water must flow from the hot water faucet before 
turning “ON” power. The manufacturer will not warrant any elements 
damaged by failure to follow instructions.
15. Check element for water leaks. If leakage occurs, tighten element. 
If necessary drain tank before repeating Steps 7 and 8, remove 
element and reposition gasket. Then repeat Steps 10 through 15.
16. Replace the two spade connectors on element into their original 
positions.
17. Replace the mounting bracket with the center rise facing outward 
and the screw hole up, see Figure 10.
18. Replace the insulation and front panel, lining up the three tabs at 
the top with the slots in the casing.
19. Replace the retaining screw and the temperature knob.
20. Plug heater into electrical outlet.
fiGure 10.
TO  REMOVE AND  REPLACE ANODE:
1.  Follow steps 1-8 of the Element Cleaning/Replacement section.
2.  Using a 7mm wrench, remove the nut securing the anode.
3.  Unscrew and remove anode.
4.  Screw in the new anode and secure with the retaining nut. 
5.  Follow  instructions  for  replacing  the  element  in  “ELEMENT 
CLEANING/REPLACEMENT.”
hiGh limit switch removal and replacement
1.  Turn off and unplug the heater from the electrical outlet.
2.  Remove the front panel, see the “REMOVING THE FRONT 
PANEL” section in this manual.  Remove the insulation pad. 
Remove personnel barrier.
3.  Remove the four wires connected to the switch, taking care 
to note the original placement of each wire.
4.  Using  a  7mm  wrench,  remove  the  nuts  securing  the  high 
limit  switch  to  the  tank  enough  to  rotate  the  switch  90° 
counterclockwise and slide it out from beneath the bracket. 
It is not necessary to remove the nuts completely. 
5.  Place the new switch beneath the bracket and rotate it 90° 
clockwise.
note: the taller spade terminal will be on the right side.
fiGure 11.
6.  Replace and tighten the nuts so the high limit switch is firmly 
in contact with the tank surface.
7.  Replace the four wires, taking care that they are replaced 
into their original positions and tighten screws.
8.  Replace personnel barrier; replace insulation block and the 
front panel.
service
If a condition persists or you are uncertain about the operation 
of the water heater contact a service agency.
Use  this  guide  to  check  a  “Leaking”  water  heater.    Many 
suspected “Leakers” are not leaking tanks.  Often the source of 
the water can be found and corrected.
If  you  are  not  thoroughly  familiar  with  your  water  heater  and 
safety practices, contact a qualified installer to check the water 
heater.