Enterasys 6000 Betriebsanweisung

Seite von 420
7-12
FRX/FRM 3. 3 User G uide, Rev 04
Configuring a Dial Port
If the port will be connected to an auto-dial modem, configure the parameters on the 
following screen.
Figure 7-4    X.25 Dial Port Parameters
Dial Port Parameters
Dial Support
specifies whether this port is connected to a dial modem and, if so, whether connec-
tions will be initiated through dial-in or dial-out calls. (Signaling differences prevent 
configuration for both dial-in and dial-out on the same port.)
A dial-out port will establish a link only when an outgoing X.25 call is placed, at 
which time the port will raise DTR and the attached modem will dial a stored number 
to a remote modem to establish an X.25 connection. A dial-in port will establish a link 
only when a call is received.
If this port is configured as a network trunk, the value for 
Dial Support
 must be
 
None
.
Table 7-3    X.25 Port Dial Parameters
Parameter
Valid Values
Default  Value
Dial Support
None, Dialout,  Di ali n
None
Inactivi ty Timer
 (minutes)
1–30
5
Disconnect Ti mer
 (seconds)
1–255
5
Line Setup Timer
 (seconds)
1–255
5
Node N ame= nod exyz
X.25 Port Parameters  (screen  6 of  6)
Databas e
System Memory
A D ial S upp ort
Dial In
Dial In
B I nactivity Timer  (minutes)
5
5
C D is con nect Timer (s ec)
5
5
D Line S etu p  Timer (sec)
1
1
Option: