 DANGER 
EXPLOSION HAZARD 
In the event a gas odor is detected, shut down equipment at the main shut off valve. Immediately call the 
emergency phone number of your gas supplier. 
 
 CAUTION 
If a pilot flame pilot should go out, the flow of gas to the corresponding burner is NOT interrupted. Consequently, it 
is the responsibility of the operator to check the ignition of each burner immediately EVERY TIME a burner is 
turned on. Should ignition fail after 10 seconds, turn off the burner, wait 5 minutes, and then try again. 
 
L
IGHTING 
A
FTER 
G
AS 
H
AS 
B
EEN 
S
HUT 
O
FF
 
When turning on the main gas supply to a sectional range, do the following: 
1.  Make sure that all the control knobs and power switches of all the connected appliances are in the OFF position. 
2.  Turn on the gas-supply shut-off valve(s). 
3.  Light the standing pilots of each connected appliance. 
4.  Turn on the ovens of the sectional range first, then wait six minutes before turning on the top sections. This 
enables all air to be purged from the sectional-range gas piping. 
S
HUTDOWN OF 
E
NTIRE 
R
ANGE
 
To place the range in a standby state (ready for use), turn all burner control knobs to OFF, set all thermostats to their 
lowest position, and switch all ovens OFF. The pilots will remain lit. 
To completely shut down the range for an extended period (or prior to disconnecting the gas supply), place the range 
in a standby state (as described in the previous paragraph), then turn OFF the manual shut-off valves of all gas 
supply connections. This will extinguish the pilots.