Quantum DLT-S4 Betriebsanweisung
Chapter 13 Using the Tape Drive
Firmware Update via the Library Tape Drive Interface
DLT-S4 Product Manual
118
unloads and ejects it. SCSI status indicates that firmware has been
updated (06h, 3F, 01).
Firmware Update via the Library Tape Drive Interface
13
The DLT-S4 library tape drive interface enables you to update the
firmware with a new version, or image via media update.
Follow these steps.
Follow these steps.
1
Ensure that the tape drive contains no cartridge.
2
Send the
CODE UPDATE REQUEST
command.
3
Send the library
ATTENTION
command, then check the Tape Motion
Status field of the returned General Status Packet to verify the tape
drive is in the Ready for Code Update (0x09) state.
4
Load the cartridge containing the new firmware into the tape drive.
5
Send the library
ATTENTION
command, then check the Tape Motion
Status field of the returned General Status Packet to verify the
cartridge is loading (0x07).
6
Send the library
ATTENTION
command, then check the Tape Motion
Status field of the returned General Status Packet to verify the
cartridge is in the CUP
in Progress (0x0A) state.
7
Send the library
ATTENTION
command, then check the Policy
Firmware Revision field to verify that the update completed
successfully.
Note:
If the tape drive is mounted in a tape automation library,
the CUP/FUP cartridge rewinds to BOT and unbuckles in
preparation for unloading, but does not automatically
eject. Use the applicable library command to eject the
cartridge.
Note:
It takes about 1 minute to enter the CUP
in Progress (0x0A)
state.