Champion pp-3 Benutzerhandbuch

Seite von 67
C O N T R O L   P A N E L S  
 
Drain State 
When the timer t expires, the controller will change from the RUN STATE to the DRAIN 
STATE. 
¾  Display shows drn 
¾  Change Water indicator light flashes 
¾  Heater is enabled 
¾  Pumps are OFF 
¾  Soap Pump is disabled 
 
The activation of alarm a l . 1   will automatically place the controller into the FILL STATE. 
The FILL STATE can also be entered by pressing and holding the UP and START/STOP 
buttons in for 15 seconds. 
Stop State 
If an operator presses the START/STOP button while in the RUN STATE, the controller 
will change to the STOP STATE. 
¾  Display shows the water temperature 
¾  Change Water indicator light if OFF 
¾  Heater is enabled 
¾  Pumps are OFF 
¾  Soap Pump is enabled 
¾  Timer t is paused 
¾  Timers t2 and t3 do not pause 
 
The controller will return to the RUN STATE if the operator presses the START/STOP 
button. 
The activation of alarm a l . 1  will automatically place the controller into the FILL STATE. 
 
AL2 State 
While in the RUN STATE or STOP STATE, the controller will enter the AL2 STATE if 
the water temperature sensor enters into an alarm condition. 
¾  Display shows  a l . 2  
¾  Alarm indicator light is ON 
¾  Heater is disabled 
¾  Pumps are OFF 
¾  Timer is paused 
¾  Timers t2 and t3 do not pause 
24