Trouble Shooting 
 
SYMPTOM FAULT 
CORRECTION 
Error code 50 on the display  Error in storing parameters in memory 
Cycle the power. Replace the control 
electronics if the problem does not clear 
Error code 61 on the display  Calibration of the water temperature 
sensor is faulty 
Recalibrate the water temperature input 
Error code 65 on the display  Calibration of the sheath temperature 
sensor is faulty 
Recalibrate the sheath temperature sensor 
Error code 67 on the display  The reference junction calibration is 
faulty 
Recalibrate the reference junction 
Error code 70 on the display  Operation parameters are set incorrectly 
or are corrupted 
Access the op.5 supervisor mode and set the 
parameters correctly 
Error code 80, 81, and 82 on 
the display 
Calibration related errors 
Recalibrate the controller 
The heat light is on, but the 
water temperature reading is 
failing 
The heater / SSR circuit may have 
failed, or the water temperature sensor 
may have been wired backwards. 
Check to see if the SSR light is on. Verify 
that the SSR output is not permanently open. 
Verify that the water temperature sensor is 
not wired backwards 
The heat light is on, but the 
sheath temperature is falling 
The sheath temperature sensor may be 
wired backwards 
Verify that the sheath temperature sensor is 
not wired backwards 
The water is agitated, but not 
at the normal frequency 
One of the two circulation pumps may 
be bad 
Check to see if either of the pumps have 
failed 
The soap pump comes on, 
but no soap is dispensed 
The soap dispensing solenoid may have 
failed 
Check to see if the soap dispensing solenoid 
has failed 
The controller display reads -
00
 
A temperature sensor is under range, 
meaning that it is very cold, or wired 
backwards 
Rewire the temperature sensors 
The basin is full of water, 
but the controller remains in 
the FIL state and alarm light 
is flashing 
Either the water temperature or sheath 
temperature sensor has failed open 
Check the temperature sensors for continuity
The heat light is off, but the 
water temperature continues 
to rise excessively above the 
desired set point 
The SSR device has likely shorted, 
forcing the heater to always be on 
Replace the SSR device 
The controller will not exit 
the drain mode during a 
change water cycle 
The heater has likely failed 
Replace the heater 
 