Enterasys csx200 Betriebsanweisung

Seite von 261
WAN Configuration Using Local Management
CSX200 Family User’s Guide
139
 shows a sample Time Slot configuration for three sites. Of the 24 Time Slots, Site #1 
uses 16 to communicate with Site #2 and the remaining 8 to communicate with Site #3. This 
configuration varies tremendously depending on how the service provider maps out the T1 Time 
Slots. Your service provider will tell you which Time Slots are active.
Figure 66
 
Sample Time Slot Configuration
Site #1 is using the full T1, so all the Time Slots must have an Interface assignment. Site #2 and 
Site #3 use only a fraction of the T1, but the total quantity of Time Slots must match those of Site 
#1. Unused Time Slots receive an Interface number of 000.
NOTE
The Interface numbers of Site #1, Site #2 and Site #3 do not have to match. Only the 
quantity of Time Slots must match (the service provider assigns the Time Slots).
SITE #2
01-08
09-16
17-24
SITE #3
01-08
09-16
17-24
SITE #1
01-08
09-16
17-24
1482_03
005
005
000
005
005
000
005
005
000
005
005
000
005
005
000
005
005
000
005
005
000
005
005
000
006
000
000
006
000
000
006
000
000
006
000
000
006
000
000
006
000
000
006
000
000
006
000
000
005
005
006
005
005
006
005
005
006
005
005
006
005
005
006
005
005
006
005
005
006
005
005
006