Enterasys csx200 Betriebsanweisung

Seite von 261
WAN Configuration Using Local Management
146
CSX200 Family User’s Guide
The line configuration information shown in 
 must be supplied by the service provider.
Fractional T1 Physical Configuration
Begin the physical configuration by accessing the WAN Physical Configuration screen through 
Local Management. Proceed with the following steps:
1.
Use the arrow keys to highlight Time Slot View. Press the SPACEBAR until NEW displays, 
then press ENTER. The cursor moves to Time Slot #1 of the Time Slot Configuration Table.
2.
Insert an interface number (see NOTE below) into every Time Slot being used (in the example 
shown in 
number, press ENTER, then use the arrow keys to highlight the next Time Slot field. Exit this 
field by using the arrow keys.The cursor automatically moves to the T1 Line Coding field.
3.
Use the arrow keys to highlight T1 Line Coding. Use the SPACEBAR to select B8ZS or AMI
then press ENTER.
4.
Use the arrow keys to highlight T1 Frame Type. Use the SPACEBAR to select ESF or D4
then press ENTER.
Table 15 Telco Configuration Information
Configuration Information 
Required by User
Information Supplied by Service 
Provider
Line Coding
B8ZS or AMI
Frame Type
ESF or D4
Clock Source
Loop Timing or Local Timing
DS-0s (Time Slots)
Time Slots being used for each end of 
the circuit
NOTE
The value assigned to the Time Slots is the interface being used for WAN 
communication. The available interface range is displayed on the WAN Physical 
Configuration screen. You may insert any of the available interface numbers into the 
Time Slots.
In the example shown in 
, the interface range for the CSX200 is 2–25. 
Although any of these values may be used, Cabletron Systems recommends using the 
first available interface number (in this example interface #2).
The following four steps are based on information supplied by the service provider. 
Consult the service provider for the correct settings.