FortiSwitch-5003 module
Inserting a FortiSwitch-5003 module into a chassis
FortiGate-5000 Series Hardware Guide
01-00000-0293-20060315
01-00000-0293-20060315
87
Connectors
lists and describes the FortiSwitch-5003 connectors.
Inserting a FortiSwitch-5003 module into a chassis
The following procedure describes how to correctly use the FortiSwitch-5003
mounting components shown in
mounting components shown in
to insert a FortiSwitch-5003 module
into a FortiGate-5000 series chassis slot. The FortiSwitch-5003 module left
extraction lever contacts a hidden power switch.
extraction lever contacts a hidden power switch.
The FortiSwitch-5003 module left extraction lever contacts to a hidden power
switch. The module must be fully installed in a chassis slot and this extraction
lever must be closed and locked for the FortiSwitch-5003 module to receive power
and operate normally. If the FortiSwitch-5003 module is not receiving power, the
Hot Swap LED glows blue and all other LEDs remain off.
switch. The module must be fully installed in a chassis slot and this extraction
lever must be closed and locked for the FortiSwitch-5003 module to receive power
and operate normally. If the FortiSwitch-5003 module is not receiving power, the
Hot Swap LED glows blue and all other LEDs remain off.
OK
Green
Initialization completed successfully.
EXT FLT
Yellow
Cannot establish a link to a configured port or another
connection problem external to the adaptor.
connection problem external to the adaptor.
INT FLT
Yellow
Failure of internal tests. Off during power up.
Hot Swap
Blue
Light on indicates the switch is ready to remove. During a hot
swap, LED is on. LED turns off when the switch is correctly
installed.
swap, LED is on. LED turns off when the switch is correctly
installed.
Reset
Press and hold Reset for three seconds to restart the switch.
LED Mode
Change the port LED display function from Link/Activity mode
to Link/Speed mode.
to Link/Speed mode.
Table 15: FortiSwitch-5003 module LEDs (Continued)
LED
State
Description
Table 16: FortiGate-5003 connectors
Connector Type
Speed
Protocol
Description
ETH0
RJ-45 100Base-T
Ethernet
Ethernet out of band management
connection.
connection.
CONSOLE RJ-45 9600 bps
RS-232
serial
serial
Serial connection to the command line
interface.
interface.
ZRE0,
ZRE1,
ZRE2
ZRE1,
ZRE2
RJ-45 1000Base-T Ethernet
Redundant connections to another
FortiGate chassis.
FortiGate chassis.