Fortinet fortigate-5001a Hardwarehandbuch

Seite von 97
FortiSwitch-5003 module 
Inserting a FortiSwitch-5003 module into a chassis
FortiGate-5000 Series   Hardware Guide
01-00000-0293-20060315
87
Connectors
 lists and describes the FortiSwitch-5003 connectors.
Inserting a FortiSwitch-5003 module into a chassis
The following procedure describes how to correctly use the FortiSwitch-5003 
mounting components shown in 
 to insert a FortiSwitch-5003 module 
into a FortiGate-5000 series chassis slot. The FortiSwitch-5003 module left 
extraction lever contacts a hidden power switch.
The FortiSwitch-5003 module left extraction lever contacts to a hidden power 
switch. The module must be fully installed in a chassis slot and this extraction 
lever must be closed and locked for the FortiSwitch-5003 module to receive power 
and operate normally. If the FortiSwitch-5003 module is not receiving power, the 
Hot Swap LED glows blue and all other LEDs remain off.
OK
Green
Initialization completed successfully.
EXT FLT
Yellow
Cannot establish a link to a configured port or another 
connection problem external to the adaptor.
INT FLT
Yellow
Failure of internal tests. Off during power up.
Hot Swap
Blue
Light on indicates the switch is ready to remove. During a hot 
swap, LED is on. LED turns off when the switch is correctly 
installed.
Reset
Press and hold Reset for three seconds to restart the switch.
LED Mode
Change the port LED display function from Link/Activity mode 
to Link/Speed mode.
Table 15: FortiSwitch-5003 module LEDs  (Continued)
LED
State
Description
Table 16: FortiGate-5003 connectors
Connector Type
Speed
Protocol
Description
ETH0
RJ-45 100Base-T
Ethernet
Ethernet out of band management 
connection.
CONSOLE RJ-45 9600 bps
RS-232 
serial
Serial connection to the command line 
interface.
ZRE0, 
ZRE1, 
ZRE2
RJ-45 1000Base-T Ethernet
Redundant connections to another 
FortiGate chassis.