SOLENOID VALVE (COLD WATER - OPTIONAL)
FIG. 29 COLD WATER SOLENOID VALVE
P1637.40
Location:
 
The cold water solenoid valve is located on the left 
side of the dispenser base just behind the component 
bracket.
Test Procedures:
1.   Disconnect the dispenser from the power source.
2.  Disconnect the white and white/yellow wires from 
the solenoid valve. With the “HOT/COLD” switch in 
the “COLD” (upper) position press the  left dispense 
switch on front of the door.
3.  With a voltmeter, check the voltage across the white 
and white/yellow wires. Connect the dispenser to 
the power source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models, three 
wire 120/208 volt, and 120/240 volt models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
4.  Disconnect  the  dispenser    from  the  power 
source.
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to Wiring 
Diagrams and check dispenser wiring harness.
5.  Check for continuity across the solenoid valve coil 
terminals.
If  continuity  is  present  as  described,  reconnect  the 
white and white/yellow wires to the solenoid.
If continuity is not present as described, replace the 
solenoid valve.
6.  Check the solenoid valve for coil action. Connect the 
dispenser to the power source. With “HOT/COLD” 
switch in the “COLD” (upper) position press the left 
dispense switch and listen carefully in the vicinity 
of the solenoid valve for a “clicking” sound  as the 
coil magnet attracts.
7.  Disconnect the dispenser from the power source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the water line before the solenoid valve or, the 
solenoid valve may require inspection for wear, and 
removal of waterborne particles.
If  the  sound  is  not  heard  as  described,  replace  the 
solenoid valve.
Removal and Replacement:
1.  Loosen the two screws securing the component 
bracket to the dispenser base. Lift the component 
bracket off of the base and move to the right.
2.  Remove the white and white/yellow wires from the 
solenoid valve.
3.  Turn off the water supply to the dispenser.
4.  Disconnect the water lines to and from the solenoid 
valve.
5.  Loosen the two #8-32 screws and washers secur-
ing  the  solenoid  mounting  bracket  to  the  base. 
Remove solenoid bracket and solenoid valve as an 
assembly.
6.  Remove  the  two  #10-32  screws  and  lockwash-
ers  securing  the  solenoid  valve  to  the  solenoid 
bracket.
7.  Using  two  #10-32  screws  and  lockwashers  in-
stall  new    solenoid  valve  on  solenoid  mounting 
bracket.
8.  Install the solenoid valve and bracket on the dis-
penser base and tighten the two #8-32 screws.  
9.  Securely  fasten  the  water  lines  to  and  from  the 
solenoid valve.
10. Refer to Fig. 30 when reconnecting the wires.
SERVICE (cont.)
29170 090407
P1215
WHI/YEL to Hot/
Cold Switch
WHI to Main Wiring 
Harness
FIG. 30 COLD WATER SOLENOID TERMINALS