Bunn FMD-3 Betriebsanweisung

Seite von 42
35
FIG. 32 DISPENSE SOLENOID VALVE 
TERMINALS
P1645
LEFT
CENTER
RIGHT
TAN to Main Harness
WHI to Main
Harness
ORN to Main
Harness
WHI to Main
Harness
WHI/VIO to Main
Harness
WHI to Main
Harness
SERVICE (cont.)
SOLENOID VALVES (DISPENSE)
FIG. 31 DISPENSE SOLENOID VALVES
P1637.40
Location:
 
The dispense solenoids are located on the upper 
left side of the tank.
Test Procedures:
1.   Disconnect the dispenser from the power source.
2.  Disconnect the white and white/violet, orange or 
tan wires from the solenoid valve. With the “RUN/
RINSE”  switch  in  the  “RINSE”  (upper)  position 
press the appropriate dispense switch on front of 
the door.
3.  With a voltmeter, check the voltage across the white 
and white/violet, orange or tan wires. Connect the 
dispenser to the power source. The indication must 
be:
 
a) 120 volts ac for two wire 120 volt models, three 
wire 120/208 volt, and 120/240 volt models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
4.  Disconnect the dispenser from the power source,
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to Wiring 
Diagrams and check dispenser wiring harness.
5.  Check for continuity across the solenoid valve coil 
terminals.
If  continuity  is  present  as  described,  reconnect  the 
white  and  white/violet,  orange  or  tan    wires  to  the 
solenoid.
If continuity is not present as described, replace the 
solenoid valve.
6.  Check the solenoid valve for coil action. Connect the 
dispenser to the power source. With “RUN/RINSE” 
switch in the “RINSE” (upper) position press the 
appropriate dispense switch and listen carefully in 
the vicinity of the solenoid valve for a “clicking” 
sound  as the coil magnet attracts.
7.  Disconnect the dispenser from the power source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the tank water outlet before the solenoid valve 
or, the solenoid valve may require inspection for wear, 
and removal of waterborne particles.
If  the  sound  is  not  heard  as  described,  replace  the 
solenoid valve.
Removal and Replacement:
1.  Remove the white and white/violet,orange or tan 
wires from the solenoid valve.
2.  Turn off the water supply to the dispenser.
3.  Drain enough water from the tank (approximately 
1.0 gallon) so the water level is below the dispense 
valve mounting hole.
4.  Disconnect  the  water  line  from  the  solenoid 
valve.
5.  Remove the  #10-32 screw securing the solenoid 
valve to side of the tank. Remove solenoid valve. 
6.  Using the  #10-32 screw install new solenoid valve 
on side of the tank
7.  Push  the  water  line  onto  the  tube  on  bottom  of 
solenoid valve.
8.  Refer to Fig. 32 when reconnecting the wires.
29170 090407