SERVICE (cont.)
SOLENOID VALVE (INLET)
FIG. 33 INLET SOLENOID VALVE
P1445.40
Location:
 
The inlet solenoid is located inside  on the left rear 
of the dispenser housing.
Test Procedures:
1.   Disconnect  the  dispenser    from  the  power 
source.
2.  Disconnect  the  white  and  violet  wires  from  the 
solenoid valve. 
3.  With a voltmeter, check the voltage across the white 
and violet wires. Connect the dispenser to the power 
source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models, three 
wire 120/208 volt, and 120/240 volt models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
4.  Disconnect the dispenser from the power source,
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to the Wiring 
Diagrams and check dispenser wiring harness.
5.  Check for continuity across the solenoid valve coil 
terminals.
If  continuity  is  present  as  described,  reconnect  the 
white and violet wires to the solenoid.
If continuity is not present as described, replace the 
solenoid valve.
29170 090407
6.  Check the solenoid valve for coil action. Connect 
the dispenser to the power source.  Listen carefully 
in the vicinity of the solenoid valve for a “clicking” 
sound  as the coil magnet attracts.
7.  Disconnect the dispenser from the power source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the water line before the solenoid valve or, the 
solenoid valve may require inspection for wear, and 
removal of waterborne particles.
If  the  sound  is  not  heard  as  described,  replace  the 
solenoid valve.
Removal and Replacement:
1.  Remove the white and violet wires from the sole-
noid valve.
2.  Turn off the water supply to the dispenser.
3.  Disconnect the water lines to and from the solenoid 
valve.
4.  Loosen the two #8-32 screws securing the solenoid 
to the rear dispenser housing. Remove solenoid.
5.  Remove the two #8-32 U-Type fasteners from the 
solenoid bracket.
6.  Install the two #8-32 U-Type fasteners and the two 
#8-32 screws on the new solenoid. 
7.  Install  new  solenoid  valve  on  rear  of  dispenser 
housing and tighten the two screws.
8.  Securely  fasten  the  water  lines  to  and  from  the 
solenoid valve.
9.  Refer to Fig. 34 when reconnecting the wires.
P1217
FIG. 34 INLET SOLENOID VALVE TERMINALS
WHI to Main
Harness
VIO to Control
Board J4-2