Canon galvano gc-251 Benutzerhandbuch
CANON Digital Galvano Scanner System
KP-1SM Series + GC-251
Users Manual 1.00
52
7.2. Command
Details
Command ID
0
Command
Name
Soft Reset
Data
0: Reset + Automatic homing
1: Reset only
1: Reset only
Return
Value
0: Command execution successful
1: Command execution unsuccessful
1: Command execution unsuccessful
Explanation
This command resets the system to the initial status after activation.
However, the parameter values are retained.
If a high-priority error requiring soft reset occurs (see 9-2, “Errors” for details), execute
this command after solving the cause.
However, the parameter values are retained.
If a high-priority error requiring soft reset occurs (see 9-2, “Errors” for details), execute
this command after solving the cause.
Related
Command
Command ID = 2: Homing Start
If only reset is executed, homing is necessary for a return.
Command ID
1
Command
Name
Error Clear
Data
-
Return
Value
0: Command execution successful
1: Command execution unsuccessful
1: Command execution unsuccessful
Explanation
If a low-priority error occurs (see 9-2, “Errors” for details), execute this command for a
return. If this command is not executed, other commands cannot be accepted. The
parameters and other set values are retained.
return. If this command is not executed, other commands cannot be accepted. The
parameters and other set values are retained.
Command ID
2
Command
Name
Homing Start
Data
-
Return
Value
0: Command execution successful
1: Command execution unsuccessful
1: Command execution unsuccessful
Explanation
This command detects the origin.
If the status is already SYNC after origin detection, this command executes homing to
the origin only.
If the status is already SYNC after origin detection, this command executes homing to
the origin only.
Related
Command
Command ID = 0: Soft Reset
If only soft reset is executed, origin detection is necessary.