Sending Images to FTP Server — FTP client setting Menu
51
OK/Cancel
Periodical sending Tab — Setting 
the Periodical FTP Client Activity
You can set to send an image file to FTP server 
periodically.
Periodical sending
Select On when you want to use periodical sending. If 
you select Off, Periodical sending is not executed.
Remote path
Type the remote path up to 64 characters.
Image file name
Type the file name of the image sent to FTP server up to 
10 alphanumeric characters, - (hyphen) and _ (under 
score).
Note
You cannot send the audio file by using the periodical 
sending function of FTP.
Suffix
Select a suffix to be added to the file name sent to FTP 
server.
None: The name of the sent file will be the Image file 
name.
Date & time: The date & time suffix is added to the 
Image file name.
The date & time suffix consists of lower two-digits of 
year (2 digits), month (2 digits), date (2 digits), hour 
(2 digits), minute (2 digits) and second (2 digits), and 
consecutive number (2 digits), thus 14-digit number 
is added to the file name.
Sequence number: A consecutive number of 10 digits 
between 0000000001 and 4294967295 and two fixed 
digits 00 is added to the Image file name.
Sequence number clear
Click Clear and the suffix of the sequence number 
returns to 1.
Mode
Select either Periodical sending mode by the timer 
management or Synchronized tour mode which sends in 
each setting position during Tour.
When you select Periodical sending mode, set Interval 
and Effective period.
Interval
Type the interval at which you want to send images to 
the FTP server periodically. You can set the hour (H), 
minutes (M) and seconds (S) between 1 second and 24 
hours (one day).
Note
The actual interval may be longer than the set value, 
depending on the image size, image quality setting, bit 
rate and the network environments.
Effective period
Set the period when the periodical sending is effective.
Always: The periodical sending is always effective.
Schedule: You can specify the period when the 
periodical sending is effective in the schedule setting 
in the other section.
Click Schedule and the setting menu for the effective 
period is displayed. (“Setting the Schedule — 
Schedule setting Menu” on page 59)
OK/Cancel