Sony ipela snc-rz25p Benutzerhandbuch

Seite von 81
A
d
mini
s
tra
ting
 t
he 
Came
ra
Recording Images in Memory — Image memory setting Menu
53
POP server name
This is necessary when POP before SMTP is selected 
in Authentication.
Type POP (receiving mail) server name up to 64 
characters. Otherwise type the IP address of POP server. 
This setting is necessary when SMTP server that sends a 
mail authenticates using the account of POP user.
User name, password
Type the user name and the password of the user who 
has the mail account. This setting is necessary when 
SMTP server that sends a mail authenticates.
Administrator e-mail address
Type the E-mail address of the recipient of the warning 
mail (E-mail address of the camera Administrator), up to 
64 characters.
OK/Cancel
Alarm recording Tab — Setting the 
Image Memory Function when 
Detecting the Alarm
You can set to record the image and audio file to the 
memory linked with the external sensor input or with the 
built-in motion detection function.
Alarm recording
Select On to set to record the image and audio file to the 
memory linked with the external sensor input or with the 
built-in motion detection function.
Image file name
Type the file name you want to assign to the images 
when saving in the built-in memory.  You can use up to 
10 alphanumeric characters, - (hyphen) and _ 
(underscore) for naming.
Suffix
Select a suffix to add to the file name.
Date & time: The Date & time suffix is added to the 
Image file name.
The Date & time suffix consists of lower two-digits 
of year (2 digits), month (2 digits), date (2 digits), 
hour (2 digits), minute (2 digits), second (2 digits) 
and consecutive number (2 digits), thus 14-digit 
number is added to the file name.
Sequence number: A consecutive number of 10 digits 
between 0000000001 and 4294967295 and an 
consecutive 2 digits number is added to the Image 
file name.
Tip
A consecutive number added to Date & time and 
Sequence number is used to identify each of multiple 
files created with one alarm event.
Sequence number clear
Click Clear to reset the Sequence number suffix to 1.
Alarm
Select the connected alarm.
Sensor input1: The external sensor which is connected 
to sensor input1 of the camera I/O port.
Sensor input2: The external sensor which is connected 
to sensor input2 of the camera I/O port.
Motion detection: Click Motion detection button, and 
the Motion detection setting page is displayed. You 
can set the motion detection function (page 53).
Notes
• Motion detection works only when the Video mode is 
set to MPEG4 and the Cropping is set to Off.
• In the case that the synchronized preset position is 
specified, the alarm event that happens during moving 
to the preset position will be invalid.
Effective period
Set the period when the alarm detection is effective.
Always: The alarm detection is always effective.
Schedule: You can specify the period when the alarm 
detection is effective in the schedule setting in the 
other section.
Click Schedule and the setting menu for the effective 
period is displayed. (“Setting the Schedule — 
Schedule setting Menu” on page 59)