Euro-Pro g6118 Benutzerhandbuch

Seite von 6
CAUTION! 
NEVER open the 
boiler filling cap before ALL 
the remaining steam has been 
released from the steam 
generator and the steam 
generator has cooled. To 
release the steam, press the 
On/Off button to the “Off”
position and push the steam 
button on the iron until no 
more steam comes out of the 
iron. Then open the boiler filler 
cap slowly.
Read all instructions before using the EURO-PRO Operating LLC Steam Generator 
Iron and follow  all the instructions and safeguards carefully.
ADDITIONAL IMPORTANT SAFEGUARDS
DO NOT OVER TIGHTEN THE 
BOILER FILLER CAP
To close the boiler filler cap, turn 
clockwise until the point where you feel 
friction – do NOT close too tightly. The 
boiler filler cap has a gasket which can 
be flattened and damaged if the cap is 
closed too tightly. If the gasket is 
damaged, steam may escape while the 
steam generator is being used. If the 
boiler filler cap is damaged and steam 
is leaking, call EURO-PRO Operating 
LLC customer service to purchase a 
replacement boiler filler cap.
NEVER LEAVE THE HOT IRON 
RESTING ON THE IRON REST 
FOR LONG PERIODS OF TIME
The lifespan of your steam generator 
will be reduced if the iron is left idle at 
high temperatures for extended 
periods of time. If the iron is not in use, 
reduce the temperature to the lowest 
temperature setting on the temperature 
control thermostat, turn the steam 
generator “Off” and remove the power 
cord from the electrical power outlet.
WARRANTED FOR REGULAR 
HOUSEHOLD USE
While the Steam Generator Iron is a 
professional type ironing system; it is 
intended for and warranted only for 
normal household use. The iron and/or 
steam generator should not be used 
for more than fifteen (15) hours per 
week in approximately three (3) hour 
intervals.
TROUBLSHOOTING
Do not operate the steam generator with a damaged cord, plug or if the iron or any 
other part of the system has been dropped or damaged.  To avoid the risk of electric 
shock, do not disassemble or attempt to repair the ironing system.  Return the 
appliance to EURO-PRO Operating LLC (see Warranty) for examination and repair. 
Incorrect re-assembly or repair can cause a risk of electric shock or injury to persons 
when the ironing system is used.
POSSIBLE CAUSES
SOLUTIONS
1. Order new boiler filler cap 
from customer Service at  
1 (800) 798-7398.
1. Gasket is broken because 
boiler filler cap was closed too 
tightly or cap was opened 
while tank was full of steam 
and gasket broke.
Steam Leaking 
From The Boiler 
Filler Cap
1. Clean steam generator as 
per instructions.
2. Use demineralized/ distilled 
water after cleaning the 
tank.
1. Residue is water tank.
2. Not using demineralized/ 
distilled water.
Dirty Or Yellow 
Steam Is 
Coming Out Of 
The Iron
1. Turn the temperature 
control dial to the marks 
between 2 and 3 dots.
2. Wait for generator to be 
fully heated.
1. Soleplate temperature is too 
low to iron with steam.
2. Generator is not fully heated.
Drops Of Water 
Leak From The 
Iron Soleplate
1. Turn the temperature 
control dial to the desired 
setting.
1. Temperature is set at 
“Minimum”.
The Soleplate 
Remains Cold
1. Press the On/Off button to 
the “ON” position.
2. Fill with water as per 
instructions.
3. Make sure that the On/Off 
button is in the “OFF” 
position and plug the unit 
into an electrical outlet.
4/5. The heating time for the 
generator is approximately 
11-13 minutes. Watch for 
the steam ready light to go 
off indicating that steam is 
ready.
1. On/Off button is not in the 
“ON” position.
2. Steam generator has no more 
water.
3. Unit is not plugged in.
4. Steam is not visible because 
the temperature of the 
soleplate is at maximum and 
room temperature is high.
5. Generator is not fully heated.
No Steam Is 
Released 
Through The 
Iron
PROBLEM
A WORD ON WATER
For best results we recommend using 
100% demineralized/distilled water.
You can use regular tap water in your 
steam generator, but should the water in 
your area be hard water we strongly 
recommend the use of 100% 
demineralized/distilled water. This will 
prolong the life of your generator and 
reduce the frequency of required generator 
cleaning, as well as the possibility of 
staining due to accumulated impurities.
DO NOT USE WATER PROCESSED 
THROUGH A HOME WATER 
SOFTENING SYSTEM OR BOTTLED 
MINERAL WATER.
DO NOT OVERFILL THE STEAM 
GENERATOR
When empty, the steam generator can be 
filled with 26 U.S. fl. oz. of demineralized/ 
distilled water. Do NOT overfill. Overfilling 
the water tank can cause water drops to 
come out of the steam holes. See filling 
instructions on page 5.
9
2