18.9
AT^SNFA Set or query of microphone attenuation 
 specifies the large-scale attenuation on the microphone path of the audio device currently selected
The write command is only available in audio modes 2 to 6. 
Syntax
Parameter Description
Multiplication factor for input samples. Parameter 
 is identical with 
 of 
Formula used to calculate microphone attenuation (negative gain):
Gain in dB = 20 * log(
/32768)
0...32767
(P)
...65535
0
Microphone is muted. 
Please note that 
 cannot be used to mute the microphone. Therefore,
any attempt to enter 0 will be rejected with error response. Value 0 is returned
only by the read command 
? after the microphone was muted with
=0 during an active call. 
32767
No attenuation on the microphone path
Values greater than 32767 will be suppressed to 32767. 
Notes
• This command is provided for compatibility with former products (e.g. M20) and is a subset of 
. The
parameter 
 is identical with 
• To make the changes persistent use 
Test Command
AT^SNFA=?
Response(s)
^SNFA: 
(list of supporte
s) 
OK
Read Command
AT^SNFA?
Response(s)
OK
Write Command
Response(s)
OK
ERROR
CME ERROR: <err>
Reference(s)
PIN
ASC0 ASC1 USB MUX1 MUX2 MUX3 Charge