Copernicus GPS Receiver     1 2 5
TRIMBLE STANDARD INTERFACE PROTOCOL (TSIP)     A
The dynamic modes are Land, Sea and Air
In packet description of 0xBB, Navigation Configuration:
Byte 1, only value 0, automatic is supported
Byte 2, is now used for SBAS
Byte 3, only values 1, 2, and 3 are supported
Bytes 9-12, change AMU mask (not supported) 
Bytes 13-21 are changed to reserved.
In packet 0x1E:
byte 0 - add 0x4D for enter Monitor Mode. The response packet is 0x5F-FF-
‘*’-‘*’-‘*’-‘ ‘-‘M’-‘O’-‘N’-‘I’-‘T’-‘O’-‘R’-‘ ‘-‘*’-‘*’-‘*’. 
0x35/0x55 packets – “Filtered PR’s in 5A” is not supported.
0x3A/0x5A packets, Raw Measurement diagnostic packets have been added to 
the Copernicus GPS Receiver. 
0x45 packet, Byte 9, “Year number minus 1900” instead of “Year number 
minus 2000.
In the 0x7A packet of the Copernicus GPS Receiver, the NMEA sentences TF 
and BA have been added.
0xBC, Protocol Configuration:
Byte 1, Two new baud rates have been added: value 10 (57600 baud), and 
value 11 (115200 baud)
Byte 3, only value 3 (8 data bits) is supported. 
Byte 4, only value 0 (No Parity) is supported.
Byte 5, only value 0 (1 Stop Bit) is supported.
8E-4A, PPS Configuration:
Byte 3, Polarity, BYTE, 0 = Positive, 1 = Negative
0x8E-17/0x8E-18, Set/Request UTM output are supported in Copernicus GPS 
Receiver.
The new packet 0x1C has been added to the Copernicus GPS Receiver. Lassen 
iQ FW v1.16 also supports this packet.