Lennox gas stove Benutzerhandbuch

Seite von 30
1
v
ent
 p
arts
 l
ist
Direct vent pipe Security™ Secure Vent™ * may be used
with the Vision™ gas stove. Please see the lists below to
verify the components available from each direct vent pipe
manufacturer.  Snorkel  terminations  are  available  for  ap-
plications which may require vertical rise on the building
exterior. The components listed below come in a galvanized
finish. Most of the components are also available in a painted
black finish. Add a “B” to the end of the part number when
ordering if a black part is desired.
s
eCurity
 - s
eCure
 v
ent
 6-5/8”
x
 4” p
ipe
Part Number  Description
SV4LC  
6” Pipe Length
SV4L12  
12” Pipe Length
SV4L24  
24” Pipe Length
SV4L36  
36” Pipe Length
SV4L48  
48” Pipe Length
SV4LA  
6” Pipe, Adjustable
SV4LA12
12” Pipe, Adjustable
SV4FA  
Flashing, 1/12 to 6/12 Roof Pitch
SV4FB  
Flashing, 7/12 to 12/12 Roof Pitch
SV4RSM
Wall Radiation Shield
SV4E46  
45º Elbow
SV4E90  
90º Elbow
SV4VS  
Vinyl Shield Protector
SV4FC  
Storm Collar
SV4CGV
Vertical Termination Cap
SV4BF  
Firestop
SV4CHC
Horizontal Termination Cap
SV4STC36
Snorkel Termination Cap (36”)
SV4STC14
Snorkel Termination Cap (14”)
SV4BM  
Wall Band
Simpson Dura-Vent GS 6-5/8”x 4” Pipe
Part Number
Description
908
6” Pipe Length
907
9” Pipe Length
906
12” Pipe Length
904
24” Pipe Length
903
36” Pipe Length
902
48” Pipe Length
911
11” to 14-5/8” Pipe, Adjustable
942
Wall Thimble
940
Rnd Support Box/Wall Thimble Cover
941
Cathedral Ceiling Support Box
943
Flashing, 0/12 to 6/12 Roof Pitch
943S
Flashing, 7/12 to 12/12 Roof Pitch
945
45º Elbow
990
90º Elbow
950
Vinyl Siding Standoff
953
Storm Collar
963
Ceiling Firestop
988
Wall Strap
981
Snorkel Termination (36”)
982
Snorkel Termination (14”)
984
Horizontal Termination Cap
985
Horizontal Termination Cap (High Wind)
980
Vertical Termination Cap
991
Vertical Termination Cap (High Wind)
h
orizontal
 v
ent
 i
nstallation
v
enting
 
terminals
 
may
 
not
 
be
 
reCessed
 
into
 
a
 
wall
 
or
 
siding
.
1) Set the unit in the desired location. Check whether or
not wall studs are in the way when the venting system is
attached. If wall studs are in the way, you may want to
adjust the location of the unit.
2) Assemble the desired combination of pipe and elbow to
the appliance adaptor with pipe seams facing down. Off-
setting the pipe seams as double seams in one place will
cause the outer pipe to take an oval shape. The Horizontal
Termination Kit comes with 18” of straight vent - 6-5/8”
black outer pipe and 4” inner vent.
3) With the pipe attached to the stove, slide the stove into
its correct location, and mark the wall to the dimensions
of  the  wall  thimble  (9-1/4”  x  10-1/4”).  The  center  of
the round hole should line up with the centerline of the
horizontal pipe. (9-1/4” is side-to-side dimension and
10-1/4” is vertical dimension) If the wall being penetrated
is constructed of non- combustible material (i.e. masonry
block or concrete), a 7” diameter hole is acceptable.
4) The horizontal run of vent should have a 1/4” rise for every
1 foot of run toward the termination. Never allow the vent
to run downward. This could cause high temperatures
and may present the possibility of a fire.
5) The location of the horizontal vent termination on an ex-
terior wall must meet all local and national building codes,
and must not be blocked or obstructed. For External Vent
Termination Locations, see page 13.
Snorkel Terminations: For installations requiring a vertical
rise on the exterior of the building, 14-inch and 36-inch tall
Snorkel Terminations are available, as well as the standard
Riser  Vent.  Follow  the  same  installation  procedures  as
used for standard Horizontal Termination. NEVER install the
snorkel upside down.
Typical parts needed for a horizontal installation.
14” Snorkel for Vision 35
Standard Horizontal for Vision 25
Wall Thimble
Decorative Wall Trim
Pipe Length
max
min
Snorkel required for Vision 35 or
Vision 25 if horizontal run
exceeds 3 feet.
Figure 15