cortech datalog 3-europlex aplex 100 & 3gs Benutzerhandbuch

Seite von 9
Datalog 
3
 - SMS Software Application Sheet
EUROPLEX APLEX 100 & 3GS Alarm Panel Control Software - Page 2 of 9
CORTECH DEVELOPMENTS LTD
/Continued -  Connection To 3GS Panel
After all the connections have been made, switch on the 3GS panel and follow the normal cold start
procedure. The Engineers code must set up the 3GS for serial communication. Enter the Engineers
code followed by (left shift 8). Select the 3GS port to configure (Usually port 1 is used) and set the
Data format as follows:-
Printer:
No
System ID:
1 (or the panel ID in a chain system)
Access Control:
31
Log Filter:
8191
Dial Mode:
0
Baud Rate:
9600 (or as set in APLEX.DAT file, see below)
Data:
8,E,1
The Datalog can now be powered up and will configure the 3GS correctly.  If a communication error
is reported by the Datalog, check that the serial wiring is correct and preferably check using a RS232
LED patch box to observe the data signals.
Connection to Aplex Panel
Connect all LEMS to the Aplex system following the normal manufacturer's procedures.  Connect
the Datalog to a serial connection on the Aplex panel following the connection diagram below (Or if
line drivers are in use consult the line driver manual).
Note connections are shown for 9 or 25 way D-type Connectors at the PC.