Lennox serefina ci2500dvf Benutzerhandbuch

Seite von 20
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
3
HI
L O W
TPTH
TP
TH
PILO
T
PIL
O
T
ON
it
OF
F
HI / LO Knob
Variable Flame Height Adjustment
Manifold Pressure Port
Inlet 
Pressure 
Port
Main Gas
Control Knob
Piezo Igniter
IN
OUT
CARBON MONOXIDE POISONING: EARLY 
SIGNS OF CARBON MONOXIDE POISONING 
ARE SIMILAR TO THE FLU WITH HEADACHES, 
DIZZINESS AND/OR NAUSEA. IF YOU HAVE 
THESE SIGNS, OBTAIN FRESH AIR IMMEDI-
ATELY. TURN OFF THE GAS SUPPLY TO THE 
APPLIANCE AND HAVE IT SERVICED BY A 
QUALIFIED PROFESSIONAL, AS IT MAY NOT 
BE OPERATING CORRECTLY.
Do not use these appliances if any part has 
been under water. Immediately call a qualifi ed, 
professional service technician to inspect 
the appliance and to replace any parts of the 
control system and any gas controls which 
have been under water.
Ne pas se servir de cet appareil s'il a été 
plongé dans l'eau, complètement ou en 
partie.  Appeler un technicien qualifi é pour 
inspecter l'appareil et remplacer toute partie 
du système de contrôle et toute commande 
qui ont été plongés dans l'leau. 
Test gage connections are provided on 
the front of the millivolt gas control valve 
(identifi ed IN for the inlet and OUT for the 
manifold side).  
These appliances must be isolated from the 
gas supply piping system (by closing their 
individual manual shut-off valve) during any 
pressure testing of the gas supply piping 
system at test pressures equal to or less 
than 1/2 psig (3.5 kPa).
These appliances and their individual shut-off 
valves must be disconnected from the gas 
supply piping system during any pressure 
testing of that system at pressures in excess 
of 1/2 psig (3.5 kPa).
These appliances must not be connected to a 
chimney or fl ue serving a separate solid fuel 
burning appliance.
Control Compartment Access
The gas controls can be found behind the lower 
access door. To  access, pull the door open 
(see Figure 2).
Millivolt appliances will be fi tted with the gas 
control valve shown in Figure 3.  Familiarize 
yourself with the gas control valve that your 
appliance uses.
OPERATION AND CARE OF YOUR
APPLIANCE
Appliance operation may be controlled through 
a remotely located optional wall thermostat or 
remote control. 
In lieu of remote or remote wall thermostat 
operation, the appliance must be operated 
directly through the on/off rocker switch located 
on the upper right side of the rear shield. See 
Figure 1.
If your millivolt appliance is equipped with an 
optional wall thermostat kit or remote control 
kit and the pilot is lit, the appliance main burner 
may be turned on and off with the wall thermostat  
or remote control.  
WARNING:  DO NOT PLACE CLOTHING OR 
OTHER FLAMMABLE MATERIALS ON OR 
NEAR THIS APPLIANCE.
AVERTISSEMENT: SURVEILLER LES 
ENFANTS.  GARDER LES VÊTEMENTS, 
LES MEUBLES, L'ESSENCE OU AUTRES 
LIQUIDES À  VAPEUR INFLAMMABLES 
LOIN DE L'APPAREIL.
WARNING: CHILDREN AND ADULTS 
SHOULD BE ALERTED TO THE HAZARDS 
OF HIGH SURFACE TEMPERATURES. USE 
CAUTION AROUND THE APPLIANCE TO 
AVOID BURNS OR CLOTHING IGNITION. 
YOUNG CHILDREN SHOULD BE CAREFULLY 
SUPERVISED WHEN THEY ARE IN THE SAME 
ROOM AS THE APPLIANCE.
WARNING:  FAILURE TO COMPLY WITH THE 
INSTALLATION AND OPERATING INSTRUC-
TIONS PROVIDED IN THIS DOCUMENT WILL 
RESULT IN AN IMPROPERLY INSTALLED 
AND OPERATING APPLIANCE, VOIDING ITS 
WARRANTY.  ANY CHANGE TO THIS APPLI-
ANCE AND/OR ITS OPERATING CONTROLS 
IS DANGEROUS.  IMPROPER INSTALLATION 
OR USE OF THIS APPLIANCE CAN CAUSE 
SERIOUS INJURY OR DEATH FROM FIRE, 
BURNS, EXPLOSION OR CARBON MONOX-
IDE POISONING.
Figure 3
SIT Millivolt Gas Valve Controls
Burner
On /Off
Switch
Top View
Front
Figure 1
Tables 3 and 4 show the units' gas pressure 
requirements
Burner On/Off Switch
Gas Controls
Lower Access Door
Pull open lower door to access Valve Contols
Lower Access
Door
Figure 2
Always keep the appliance area clear and free 
from combustible materials, gasoline and other 
fl ammable liquids.
Remember, Millivolt appliances have a continu-
ous burning pilot fl ame. Exercise caution when 
using products with combustible vapors.
Inlet Gas Supply Pressure
(all models)
Fuel #
Minimum
Maximum
Natural Gas
4.5" WC
(1.12 kPa)
10.5" WC
(2.61 kPa)
Propane
11.0" WC
(2.73 kPa)
13.0" WC
(3.23 kPa)
Table 3
Manifold Gas Supply Pressure
(millivolt models)
Fuel #
Low
High
Natural 
Gas
(Lo) 1.6" WC
(.40 kPa)
(Hi) 3.5" WC
(.87 kPa)
Propane
(Lo) 6.3" WC
(1.57 kPa)
(Hi) 10.0" WC
(2.49 kPa)
Table 4