Lennox serefina ci2500dvf Benutzerhandbuch

Seite von 20
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
5
Maintenance Task
Accomplishing Person
Procedure
Inspecting/Cleaning Burner, Logs 
and Controls
Qualifi ed Service Technician
Inspect valve and ensure it is properly operating.  Check piping 
for leaks.  Vacuum the control compartment, fi replace logs and 
burner area.
Check Flame Patterns and Flame 
Height
Qualifi ed Service Technician
Refer to Figure 7 on Page 6 and verify the fl ame pattern and 
height displayed by the appliance conforms to the picture.  Flames 
must not impinge on the logs.  Ensure fl ames are steady (not 
lifting or fl oating).
Inspecting/Cleaning Pilot and Burner
Qualifi ed Service Technician
Refer to Figure 7 (Page 6) and Figure 18 (Page 9). Remove 
any surface build-up on pilot and burner assembly.  Wipe the 
pilot nozzles, igniter/fl ame rod and hood.  Ensure the pilot fl ame 
engulfs the fl ame sensor as shown.
Checking Vent System
Qualifi ed Service Technician
Inspect the vent system at the top and at the base (within the 
fi rebox) for signs of blockage or obstruction.  Look for any signs 
of dislocation or deterioration of the vent components.  Note:  
Excessive condensation can cause corrosion of caps, pipe & 
fi ttings (excessive condensation can be caused by long lateral 
runs, too many elbows and/or exterior portions of the system 
being exposed to cold weather).  Also inspect wall straps or 
plumbers's tabe to ensure it is secure and in place.
Appliance Checkout
Qualifi ed Service Technician
Perform the appropriate appliance checkout procedure detailed 
in this manual.
Replacing Rockwool Ember Materials
Homeowner/Qualifi ed Service
Technician
Remove old ember materials and vacuum the rockwool place-
ment area.  Place new rockwool as described on Page 9 (see 
Figure 18).
Periodically (After the Burning Season)
Maintenance Task
Accomplishing Person
Procedure
Cleaning  Firebox  Interior
Homeowner
Carefully remove logs, rockwool, volcanic stone and vermiculite.  
Vacuum out interior of the fi rebox.  Clean fi rebox walls and log 
grate.  Replace logs, Rockwool and volcanic stone as detailed 
in this manual.
Check Flame Patterns and Flame 
Height
Homeowner
Refer to Figure 7 on Page 6 and verify the fl ame pattern and 
height displayed by the appliance conforms to the picture. Flames 
must not impinge on the logs.
Checking Vent System
Homeowner
Inspect the vent system at the top and at the base (within the 
fi rebox) for signs of blockage or obstruction.  Look for any signs 
of dislocation of the vent components.
Cleaning Front Glass Enclosure Panel
Homeowner
Clean as necessary following the directions provided in this 
manual.  DO NOT  TOUCH OR ATTEMPT TO CLEAN GLASS 
WHILE HOT.
Anually (Before the onset of the Burning Season)
MAINTENANCE SCHEDULE