Dacor DR30DH-C Benutzerhandbuch

Seite von 24
16
Installation Instructions
L1 terminal
L1 terminal
L2 terminal
L2 terminal
Black wire
Red wire
White wire
Green wire
Red wire
White wire
Black wire
Conduit strain 
relief nut
Conduit strain 
relief nut
Neutral terminal
Neutral terminal
Neutral to ground 
jumper link
Neutral to ground 
jumper link removed
Grounding screw
3-Wire Conduit Connection - 
Where Local Code Permits
4-Wire Conduit 
Connection 
(preferred)
Electrical Connection (cont.)
Connecting Conduit to the Range
 
WARNING
Do not connect the green appliance wire to the neutral (white) 
supply wire unless local building codes permit.
1.  Remove the range electrical access cover from the back of 
the range.
2. 
IMPORTANT: If using a 4-wire connection, loosen the 
grounding screw and remove the neutral to ground jumper 
link from the terminal block. Leave the link in place for 3-wire 
connections.
3.  Remove the nut from the conduit strain relief (not included).
4.  Slide the wires and the end of the strain relief into the hole on 
the bottom of the range electrical box.
5.  Before connecting the wires, slide the strain relief nut over 
the wires and thread it onto the conduit strain relief inside the 
box. Tighten into place.
6.  Connect the white wire to the neutral terminal in the box.
7.  Connect the black wire to the L1 power supply terminal.
8.  Connect the red wire to the L2 power supply terminal.
9.  If using a 4-wire connection, connect the green wire to the 
grounding screw inside the box.
10.  Replace the range electrical access cover.
Remove link on  
4-wire installations
Terminal 
block
Bare wire 
connections
Loop and  
spade terminal 
connections