Installation Instructions
Electrical Connection
 
WARNING
•  Wire the range only in compliance with local ordinances.
•  Before proceeding, turn off power to the electrical supply 
at the circuit breaker panel for fuse box. Do not turn on 
power to the range until instructed to do so in the Verifying 
Proper Operation section of these instructions.
•  Improper connection of the electrical wiring can cause an 
electric shock hazard and damage the appliance. Dacor 
is not responsible for damages resulting from improper 
installation.
•  The ground terminal (or lead) on the appliance must be 
connected to a grounded, metallic, permanent wiring system 
or grounding conductor.
•  Do not use an extension cord with this appliance. Such use 
may result in fire, electric shock or other personal injury.
•  Do not install a fuse in the neutral or ground circuit. A fuse 
in the neutral or ground circuit may result in an electric 
shock hazard.
IMPORTANT:
Some models come pre-wired at the factory with a 4-wire 
appliance cord for connection to a 14-50R electrical 
receptacle as specified on page 3. If the range being 
installed is pre-wired, skip to Gas Connection on page 18. 
This section does not apply to pre-wired units.
Do not disconnect any of the wires inside the range electrical 
box unless instructed to do so.
Make sure that the 
conduit or appliance 
cord is long enough 
to allow the range 
to be pulled out 
for service without 
disconnecting it from 
power.
Types of Electrical Connections
Refer to the product data label (see inside cover) for power 
requirements.
There are four possible ways to wire the range:
4-wire appliance cord, where local codes permit 
3-wire appliance cord, where local codes permit
4-wire conduit (see page 16)
3-wire conduit, where local codes permit (see page 16)
The sections on the following pages give directions for connecting 
each type of wiring harness.
Put slack in 
electrical wiring 
and gas line
Appliance Cord Connections - Where Local 
Code Permits
 
WARNING
Do not connect the green appliance wire to the neutral (white) 
supply wire unless local building codes permit.
1.  Remove the range electrical access cover from the back of 
the range.
2. 
IMPORTANT: If using a 4-wire connection, loosen the 
grounding screw and remove the neutral to ground jumper 
link from the terminal block. Leave the link in place for 3-wire 
connections.
3.  Remove the conduit bracket from the bottom of the range 
electrical box.
4.  Disassemble and remove the strain relief from the appliance 
cord (not included). Insert the tabs on the two parts of 
the strain relief into the hole on the bottom of the box and 
reassemble it so that the tabs are below the box and the 
strain relief itself is inside the box.
Remove link on  
4-wire installations
Remove conduit bracket 
before strain relief installation
Terminal block
Strain relief
Reassemble with tabs 
below and clamp above
Bottom of range  
electrical box