cortech datalog 3-molynx Benutzerhandbuch

Seite von 6
Datalog 
3
 - SMS Software Application Sheet
Molynx Visilynx CCTV Module - Page 2 of 6
CORTECH DEVELOPMENTS LTD
 
Installation
Connection
A serial connection is required between the Datalog 3 PC and the CCTV controller matrix
as shown.
The serial link between the Datalog PC and the CCTV matrix is 9600 baud, 8 Data bits, 1
start bit, Even parity and 1 stop bit. The PC connections are as follows:
PC 25 Way D
PC  9  Way
D
TTX309/PCCON2
Pin 2 (Tx)
Pin 3 (Tx)
Pin 2 (Rx)
Pin 3 (Rx)
Pin 2 (Rx)
Pin 3 (Tx)
Pin 5 (CTS)
Pin 8 (CTS)
Pin 4 (DTR)
Pin 20 (DTR)
Pin 4 (DTR)
Pin 8 (CTS)
Pin 7 (Gnd)
Pin 5 (Gnd)
Pin 5 (Gnd)
Cable distance between the PC and the CCTV matrix should not exceed 15 metres unless
suitable line drivers are used. The Datalog Communication port is shown on the Molynx
setup Window. See 
Configuration