FMI (V)B42L Benutzerhandbuch

Seite von 20
www.fmiproducts.com
109036-01M
6
FIREPLACE INSTALLATION
Continued
Figure 4 - Mantel Clearances to 
Combustible Material
Electrical 
Bushing
Electrical 
Cover 
Plate
Rocker 
Switch
Figure 6 - Fan Switch-Electrical Bushing
Electrical 
Housing
Wire Nut (3x) 
(Not Supplied)
Outer Wrapper 
of Fireplace
Electrical Cover 
Plate and 
Electrical Bushing
Fireplace Chassis 
Ground
To Power 
Source
Receptacle 
(Supplied)
Power Source Wiring 
(Not Supplied)
Prewired Receptacle 
and Ground
MANTELS
A  mantel  may  be  installed  if  desired  (see 
Figure  4).  Woodwork  such  as  wood  trims, 
mantels  or  any  other  combustible  material 
projecting from front face must not be placed 
within 12" of fireplace opening (and within 9" 
of top louver opening). Combustible materi-
als above 12" and projecting more than 1 
1
/
2
from fireplace must not be placed less than 
12" from top opening of fireplace (NFPA STD 
211, Sec. 7-3.3.3).
Mantels  or  any  other  combustible  material 
may come up to side edge of black metal face 
of fireplace if projection from front face falls 
within limits shown in Figure 5.
FAN/BLOWER KIT ASSEMBLY
Fan or blower kit is optional with this fireplace 
(for circulating models only). Use of blowers 
or  fans  other  than  those  manufactured  by 
FMI PRODUCTS, LLC voids warranty. Fan 
is  operated  by  pressing  rocker  switch  (see 
Figure 6) in lower right hand corner of fireplace 
face.  Blower  is  operated  by  turning  control 
knob (not shown).
Fan/blower  kit  electrical  connections  are 
made through electrical cover plate on side 
of fireplace a shown in Figure 6.
FIREBOX
SAFE ZONE
Figure 5 - Side Mantel Clearance
Top View of Fireplace
Min. 12" from 
Perpendicular Side Wall
1"
0.625" Max.
33°
8"
Wiring Instructions
1.  Remove electrical cover plate with bush-
ing  from  fireplace  by  removing  2  sheet 
metal screws as shown in Figure 6.
2.  Slide power source wiring through electri-
cal bushing opening and electrical cover 
plate  and  make  all  necessary  connec-
tions.
3.  Slide all wiring connections in electrical 
housing as shown in Figure 6.
4.  Secure electrical cover plate with screws 
previously removed.
Note: Electrical housing and cover plate have 
sharp edges. Wear protective gloves.
Sheet 
Metal 
Screws
12 
1
/
4
" Ref.
1
/
2
"
Max.
Upper Section
of Circulating
Fireplace
6"
Ref.
9"
Min.
33°
3" Nom.
*Note: Drawing
Not To Scale
Safe Zone For
Projection of
Combustible
Materials
Combustible
Material
15"
Min.
12"
Min.
Fireplace Opening
Top of 
Louvered
Opening