Electrical Connection – US & Canada 
1.  Verify that the actual voltage at the electrical service connection is compatible with the specifications on the 
brewer’s serial number label.  Make sure the electrical service includes neutral
2.  The temperature and water tank fill level are pre-set at the factory.  There is no need to turn off the heaters 
during the installation process.  The heaters are disabled by the control board until the tank is full of water.  The 
heating process will start automatically when the tank has filled. 
3.  The CBS-2031 is factory equipped with a 120 V cord and plug.  The CBS-2032 has only a terminal block for 
connecting the incoming power wires. Consult local codes to determine if a cord and plug can be installed, or if 
the unit must be hard wired.  
4.  A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the 
brewer, and its location and markings known to the operators. 
5.  The body of the brewer must be grounded to a suitable building ground.  
A ground lug is provided in the brewer next to the power terminal block.  
Use only 10 gauge copper wire for grounding. 
6.  Electrical connections must be secured in-place within the unit to meet 
national and local standards. 
7.  Finally, connect the incoming power wires to the terminal block as shown in accordance with applicable codes. 
 
CBS-2031e / CBS-2031s 
Can be connected to 120 VAC or 120/208-240 VAC 
Factory Configuration 
    120 VAC, 3 wires
 
 
 
 
L1 
L2 
GROUND 
CORD WITH 
 NEMA 5-20P PLUG 
L2 - NOT USED 
 
Optional Field Conversion* 
    120/208-240 VAC, 4 wires 
 
Step 1: Remove the factory provided 120 V cord & 
plug from the terminal block. 
 
Step 2: Connect the incoming wires to the terminal 
block in accordance with applicable codes. 
 
 
L1 
L2 
GROUND LUG 
GROUND 
WIRE 
208-240V 
120V 
120V 
 
 
*This procedure must be performed only by a qualified 
service technician or electrician. 
 
Notice: In order for this product to comply with the 
requirements of the Underwriters Laboratories listing, 
the following conditions apply: 
1.) This unit must be hard wired for 120/208-240 VAC. 
2.) Once the unit is converted to 120/208-240 VAC 
operation, it cannot be converted back to 120 
VAC operation. 
 
 
CBS-2032e / CBS-2032s 
Can be connected only to 120/208-240 VAC 
 
 
L1 
L2 
GROUND LUG 
GROUND 
WIRE 
208-240V 
120V 
120V 
 
 
             
Warning: To prevent 
                 electrical shock, this 
                 unit must be properly 
                 grounded.