NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
       WARNINGS
 
Improper installation, adjustment, alteration, 
service  or  maintenance  can  cause  injury  or 
property damage. For assistance or additional 
information, consult a qualified installer, service 
agency or your gas supplier.
 
Operation of this appliance when not connected 
to a properly installed and maintained venting 
system  can  result  in  carbon  monoxide  (CO) 
poisoning and possible death.
 
Carbon  monoxide  poisoning  –  early  signs  of 
carbon  monoxide  poisoning  resemble  the  flu 
with headaches, dizziness, or nausea.  If you 
have these signs, get fresh air at once!  Have 
the  heater  inspected  by  a  qualified  service 
technician.  Some people are more affected by 
carbon monoxide than others.  These include 
pregnant  women,  people  with  heart  or  lung 
disease or anemia, those under the influence 
of alcohol and those at high altitudes.
12.  Adjust the flame height (and heat output) by turning the flame 
height knob clockwise               for full flame and counter­
clockwise               for reduced flame.
13.  Turn on the electric power to the appliance and set the blower 
to the desired air flow after it turns on when the appliance 
reaches operating temperature.
TO TURN OFF GAS TO APPLIANCE
1.    Turn off the “ON/OFF” rocker switch and/or thermostat (if 
installed) to its lowest setting.
2.    Turn off electric power to the appliance if service is to be 
performed.
3.    Push in gas control knob slightly and turn clockwise
                   to “OFF.” Do not force.
SHUTDOWN PROCEDURE
To turn off the burner, turn the rocker switch to “OFF” or adjust 
the thermostat (if installed) to a setting below room temperature. 
The pilot will remain lit for future burner ignition. For complete 
shutdown, see “TO TURN OFF GAS TO APPLIANCE” above.
Flame Color and Behavior
This appliance is designed for maximum heating efficiency. Therefore, 
upon lighting of the main burner the flames will be semi­transparent or 
“bluish.” After 10­20 minutes of operation the logs will heat up and the 
flames will become a yellow/orange color.
Adjusting the appliance to cause the flames to turn orange sooner may 
result in poor combustion, sooting and a hazardous situation. See Figure 
31
 showing proper flame appearance.
When testing for proper operation ­ If an optional thermostat is installed 
adjust it to its highest temperature setting.  Visually determine that main 
burner gas is burning properly:  i.e., no floating, lifting or flashback.  
Adjust  the  primary  air  shutter(s)  as  required.  Check  for  proper  main 
burner operation at both high and low flame.
SIT Millivolt Gas Valve
Gas Control Knob 
(Pilot / On / Off)
Flame Height Control 
Knob (HI/LO)
No Blue Flame 
Center
Soot at 
Flame Tip
Dark Orange 
Flame
IMPROPERLY 
BURNING FLAME
Soot above 
Flame Tip
No Soot at 
Flame Tip
PROPERLY
BURNING FLAME
Semi-Transparent 
Yellow Flame 
Blue Flame 
Center
Ports on Pan 
Burner Assembly
Burner Flame Appearance
Figure 29
Figure 31
Figure 32
Figure 30
PILOT
ON
OF
F
HI
LO
Gas Control Knob 
(pilot/on/off)
Bouton de contrôle 
(veilleuse/ouverte/fermée)
Igniter / Allumeur 
Flame Height Control Knob
- LO / HI + 
(Commande De
Taille De Flamme)
Proper Pilot Flame Appearance