Lennox elite vint-dvs-u Benutzerhandbuch

Seite von 32
23
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Millivolt Control Schematic
Thermopile
ON/OFF Rocker Switch, 
Thermostat, or Remote 
Thermostat
Piezo Igniter
Thermocouple
Pilot Gas Line
Sparker
Pilot Hood
Pilot Assembly
Gas Inlet
Pressure Taps
Operating Options
“On-Off” Switch, Thermostat Or Remote Control
Your stove comes equipped with an “On/Off” rocker switch used to turn 
the burner on and off while the pilot light is on. The switch is a round 
rocker switch located behind the main control panel door.
A millivolt wall thermostat, or a remote control, can be used to supple­
ment the rocker switch. The gas valve is powered by millivolts generated 
by the pilot assembly. This millivolt system is very sensitive to electrical 
resistance, therefore, make sure all connections are tight, clean and free 
from corrosion. Do not splice any millivolt wires. Consult the table below 
to determine the proper gage of wire for the thermostat or wall switch 
connections. This table refers to the total length of the wire (out to the 
switch and back). The thermostat must be a millivolt type. A 24­volt 
furnace thermostat will not work. Never hook up household current ­ 120 
Volts ­ to the millivolt system. It is not recommended to hook up any 
more than two switches to the stove (for example a rocker switch and a 
wall thermostat). Additional switches may affect the system resistance 
and increase the chance of the burner not igniting.
Follow the instructions included with the thermostat or remote control 
for wiring. The thermostat, remote control and rocker switch will turn the 
burner on and off independently. Be sure to set the rocker switch to the 
“Off” position when using the thermostat or remote control and set the 
thermostat or remote control to the lowest temperature when you wish 
to use the rocker switch only, otherwise one may override the other.
Millivolt Control System
This stove operates on a millivolt control system. As such, no additional 
power supply is needed for the stove to heat. The pilot assembly contains 
a thermocouple that, when heated by the pilot flame, generates electricity 
(millivolts­ mV=1/1000 of a volt) which opens a valve allowing gas to 
continue flowing to the pilot assembly. The pilot assembly also contains a 
thermopile that, when heated by the pilot flame, generates electricity that 
flows to terminal #1 (labeled TPTH) on the gas valve. When the electricity 
is conducted from terminal #1 through the on/off switch, thermostat, 
or receiver of the remote control to terminal #3 (labeled TH) on the gas 
valve, the main burner will ignite.
CAUTION:  Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous 
operation. 
ATTENTION:    Au  moment  de  l'entretien  des  commandes, 
étiquetez tous les fils avant de les débrancher.  Des erreurs 
de  cáblage  peuvent  entraîner  un  fonctionnement  inadéquat 
et dangereux.
Figure 34
Thermostat Wire
Wire Size
Maximum Length
12 Gage
100 Feet
14 Gage
64 Feet
16 Gage
40 Feet
18 Gage
25 Feet
20 Gage
16 Feet
Terminal 3
Terminal 1 Terminal 2
Gas Valve
Wiring Terminals
PILOT
OFF
ON
HI
LO
PILO
T
TPTH
TP
TH
1
2
3
1
2
3