Lennox elite vint-dvs-u Benutzerhandbuch

Seite von 32
22
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Optional Blower Wiring Diagram
FAN SNAP SWITCH - N/O
MAIN POWER CORD
WIRE (BLACK)
GROUND WIRE
(GREEN)
MAIN POWER CORD
WIRE (WHITE)
MAIN POWER CORD
WIRE (BLACK)
FAN SPEED CONTROL
SNAP SWITCH CONNECTION 
WIRE (BLACK)
BLOWER
SPEED CONTROL 
CONNECTION WIRE 
(BLACK)
SPEED CONTROL
WIRE (RED)
SPEED CONTROL
WIRE (RED)
N/O - NORMALLY OPEN (CONTACTS CLOSE 
WHEN STOVE IS HOT) 
If the optional blower is installed, the sound of rushing air may be heard 
when the blower is on. The blower sounds may be reduced by adjusting the 
speed control located on the blower assembly. Also, a slight clicking sound 
may be heard as the gas valve or blower switch come on and off.
Paint Curing
This appliance has been painted with a high temperature metallic paint. It 
leaves the factory dry to the touch, but completes the curing process as 
the stove is used. To cure the paint, burn the appliance four successive 
times for ten minutes each time with a five minute cool down between 
each firing. Also some parts of the appliance may be lightly coated with 
machining oil. Ventilate the house during these first firings as the paint 
and oil give off carbon dioxide and unpleasant odors. It is recommended 
that persons sensitive to an imbalance in the indoor air quality avoid the 
appliance during the curing process.
Optional Wall Thermostat
If an optional wall thermostat is to be installed, install the thermostat per 
the manufacturers instructions (provided with the thermostat).  Failure 
to follow manufacturers instructions could result in a malfunction. Pay 
special attention to the thermostat location requirements. If the loca­
tion requirements are not adhered to the appliance, erratic operation or 
failure may occur.  
Do not mount the thermostat where it may be affected by:
•  Radiant  heat  from  this  appliance,  fireplaces,  sun  or  other  heat 
sources.
•  Drafts or dead spots behind doors or in corners.
•  Hot or cold air from ducts.
Optional Blower
An optional blower (part # 75194) may be installed on your stove to 
maximize heat distribution. See your Lennox Hearth Products dealer for 
blower information. The optional blower is equipped with a three­prong 
(grounding) plug for your protection against shock hazard and should 
be plugged directly into a properly grounded three­prong receptacle. Do 
not cut or remove the grounding prong from this plug.
CAUTION:  Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous 
operation. 
ATTENTION:    Au  moment  de  l'entretien  des  commandes, 
étiquetez tous les fils avant de les débrancher.  Des erreurs 
de cáblage peuvent entraîner un fonctionnement inadéquat et 
dangereux.
Air Shutter Adjustment
The air shutter control lever is located on the bottom of the stove directly 
to the left of the gas valve. The lever is linked to the primary air shutter on 
the main burner. The air shutter regulates the amount of primary air the 
burner receives and therefore how clean the stove burns. The air shutter 
should only be adjusted by a qualified gas technician. The stove should 
burn for about 15 minutes with the logs installed before adjusting the air 
shutter. Moving the lever down will open the shutter and turn the flames 
more transparent and blue. Moving the lever up will close the shutter 
and turn the flames more orange.
CAUTION:  The air shutter should never be set so as to make the 
tips of the flames sooty or create sooting on the viewing glass, 
logs, or firebox ceiling. If soot begins to form after burning, 
the air shutter should be opened gradually until the sooting 
condition stops. Gas quality and gas pressure may vary which 
can affect the burning characteristics of the stove.
Air Shutter Control Lever
Open 
Close
End View of Gas Valve
Figure 33
Quiet Operation
As the appliance is burning, a number of normal operational sounds may 
be heard. The flow of gas through the gas valve and orifice may make a 
rushing or whistling noise. If this noise is objectionable, it can be reduced 
by turning down the flame. Turning down the flame can reduce total heat 
output by more than 30%.