Mounting on a Recessed Drop-Ceiling T-Bar
The enclosed T-bar bracket supports mounting to recessed 
drop ceiling T-bars.
Mounting an AP using the External Bracket
1
Insert the unit removal pin (A in 
) into the hole on 
the side of the R600 (B in 
) to release the locking 
mechanism.
Figure 4. Attaching the external bracket to the AP
2
Position the studs on the bottom of the T-bar bracket (C 
in 
) in the mounting holes on the R600 enclosure, 
and then slide the T-bar bracket until the studs are in the 
narrow parts of the R600 mounting keyholes (arrow).
3
Remove the unit removal pin (A in 
) to engage 
the locking mechanism and secure the T-bar bracket to 
the R600.
4
Make sure that the locking tab (D in 
first position on the T-bar bracket (C in 
).
5
Gently push the ceiling tiles up and out of the way.
6
Position the T-bar bracket so its two clasps grip one edge 
of the T-bar (A in 
). Make sure that both clasps 
are gripping the T-bar.
Figure 5. Attaching the external bracket to the T-bar
7
Hold the R600 in place and gently push the locking tab 
(B in 
) until its clasp grips the other edge of the T-
bar.
Removing an External Bracket from a T-Bar
1
Move the ceiling tiles out of the way.
2
Gently lift up the locking tab (A in 
) by sliding 
your fingers under the tab. 
3
While lifting up on the locking tab, rotate the R600-
and-T-bar bracket assembly (B in 
). The R600-
and-T-bar bracket assembly comes away from the T-
bar.
Figure 6. Removing the external bracket from the T-bar
Removing an External Bracket from an AP
1
Insert the unit removal pin (A in 
on the side of the R600. 
2
Gently lift up the retainer tab (B in 
3
Gently push the T-bar bracket (C in 
detaches from the R600.
Figure 7. Removing the external bracket from an AP
Mounting on a Flush Drop-Ceiling T-Bar
Mounting an AP using the Integrated Bracket
1
Orient the AP so that the T-bar is positioned between 
the T-bar clips as shown in 
, then rotate the AP 
until the third T-bar clip catches the T-bar and the 
latch locks the T-bar in place (
).
Figure 8. Attaching the integrated bracket to the T-bar
Figure 9. Locking the integrated bracket to the T-bar
2
Insert the Torx security screw into the hole near the 
latch to lock the AP in place.
Removing an AP Integrated Bracket from a T-Bar
1
To remove the AP from a T-bar, first remove the 
security screw, then depress the latch while rotating 
the AP so that the T-bar clips disengage the T-bar.
Mounting on a Truss or Pole
1
Feed the customer-supplied cable ties through the 
two slots on the back of the R600.
2
Fasten the R600 to the truss or pole using the cable 
ties.
Note: This mounting bracket can also be used on a flush 
drop-ceiling T-bar, so the four rubber feet on the bottom 
of the AP minimize ceiling tile displacement.
A
B
C
D
A
B
CAUTION: 
Make sure that all three clasps are gripping the T-
bar! 
A
B
C
B
A