4.1.7  Page 7: Monitor Settings 
 
Picture 4-8: monitor settings 
Name 
Term 
Range 
Default  Remarks 
NFiles 
Reader data onto disk 
1 ... 999 
 
AntDisplay 
Antenna to monitor 
0 .. 2 
0= both Antennas, 1=Ant1, 2=Ant2 
TrigAnt 
Antenna to trigger 
1 .. 3 
1=Ant.1, 2=Ant2, 3=both Antennas 
Table 4-8: monitor settings 
1
 
Nfiles 
Defines the number of „pictures“ of a current identification situation which will be stored onto disk when 
using the function „save reader data onto disk“ (see chapter Remote Diagnostics on page 64). 
AntDisplay 
Select the antenna (A) which you want to look at with the service PC: 
• 
AntDisplay=0 
the data of the antennas 1 and 2 are displayed alternately 
• 
AntDisplay=1 
only the data of antenna 1 is displayed 
• 
AntDisplay=2 
only the data of antenna 2 is displayed 
TrigAnt 
Select the antenna (A) which you want to trigger with the help of key „t“ on your service PC. 
• 
TrigAnt=1 
only antenna 1 is selected to be triggered 
• 
TrigAnt=2 
only antenna 2 is selected to be triggered 
• 
TrigAnt=3 
antennas 1 and 2 are selected to be triggered 
                                                      
1 These two parameters are not saved in the  reader (R
)
. They are only used in the service PC..