Robert Bosch Pty Ltd VIMA01 Benutzerhandbuch

Seite von 38
  
 
PROTOCOL SPECIFICATION 
F005VP0801 
ROBERT BOSCH 
(AUSTRALIA) PTY. LTD. 
A.B.N. 48 004 315 628
 
SMARTRA III IMMOBILISER 
Page 16 of 49 
 
 
Issue Number: 
1.0 
Dev No.
 3881 
Valid from: 
14/2/06 
Print Date: 
28 March, 2007 
© THIS DRAWING IS THE EXCLUSIVE PROPERTY OF ROBERT  BOSCH (AUSTRALIA)  PTY. LTD.  WITHOUT THEIR CONSENT IT MAY NOT BE REPRODUCED OR GIVEN TO THIRD PARTIES. 
DEV04205.9/I-1 
 
4.5  41h - Transponder Authentication. 
 
CU Request :- 
 
49  0A  41  RN1 RN2 RN3 RN4  ELP1  ELP2  ELP3  ELP4  CS 
 
 
 
 
RN1..RN4 :- Random Number bytes (00-FF) 
 
 
 
 
ELP1.. ELP4 :- Encrypted Lock Password bytes (00-FF) 
 
SMARTRA Response :- 
 
69 05 EKP1 EKP2 EKP3 EKP4 CS 
EKP1 .. EKP4 :- Encrypted Key Password bytes (00-FF) 
 
 
Note :- SMARTRA will take up to 150ms to start sending the Authentication response to the CU. 
 
4.6  57h - Transponder Write EEPROM Page. 
 
CU Request :- 
 
49 Length  57  PN  B0  B1  B2  B3  PNn B0n B1n B2n B3n CS
 
 
 
 
PN...PNn :- Page Number byte (01-07) 
 
 
B0,B1,B2,B3...B0n,B1n,B2n,B3n :- Transponder bytes to be written (00-FF) 
 
 
 
 
 
 
 
 
SMARTRA Response :- 
 
69 02 57 59 
 
This request is only valid during the key programming procedure with the Transponder in password 
mode. 
 
Note :- 
•  SMARTRA will take up to 600ms to start sending the response to the CU when programming three 
consecutive pages. 
•  Maximum number of consecutive pages to program in the same “Transponder Write EEPROM Page” 
request is three. 
4.7  52h - Transponder Read EEPROM Page 
CU Request :- 
49 03 52  PN 
CS 
     PN 
:- 
Page 
Number 
byte 
(00-07) 
     
SMARTRA Response :- 
 69  05 
B0 
B1 
B2 
B3 
CS 
 
 
 
 
B0 .. B3 :- Transponder bytes read (00-FF) 
This request is only valid prior to key programming procedure with the Transponder in password mode. 
Note :-  