Robert Bosch Pty Ltd VIMA01 Benutzerhandbuch
PROTOCOL SPECIFICATION
F005VP0801
ROBERT BOSCH
(AUSTRALIA) PTY. LTD.
A.B.N. 48 004 315 628
SMARTRA III IMMOBILISER
Page 16 of 49
Issue Number:
1.0
Dev No.
3881
Valid from:
14/2/06
Print Date:
28 March, 2007
© THIS DRAWING IS THE EXCLUSIVE PROPERTY OF ROBERT BOSCH (AUSTRALIA) PTY. LTD. WITHOUT THEIR CONSENT IT MAY NOT BE REPRODUCED OR GIVEN TO THIRD PARTIES.
DEV04205.9/I-1
4.5 41h - Transponder Authentication.
CU Request :-
49 0A 41 RN1 RN2 RN3 RN4 ELP1 ELP2 ELP3 ELP4 CS
RN1..RN4 :- Random Number bytes (00-FF)
ELP1.. ELP4 :- Encrypted Lock Password bytes (00-FF)
SMARTRA Response :-
69 05 EKP1 EKP2 EKP3 EKP4 CS
EKP1 .. EKP4 :- Encrypted Key Password bytes (00-FF)
Note :- SMARTRA will take up to 150ms to start sending the Authentication response to the CU.
4.6 57h - Transponder Write EEPROM Page.
CU Request :-
49 Length 57 PN B0 B1 B2 B3 PNn B0n B1n B2n B3n CS
PN...PNn :- Page Number byte (01-07)
B0,B1,B2,B3...B0n,B1n,B2n,B3n :- Transponder bytes to be written (00-FF)
SMARTRA Response :-
69 02 57 59
This request is only valid during the key programming procedure with the Transponder in password
mode.
Note :-
• SMARTRA will take up to 600ms to start sending the response to the CU when programming three
consecutive pages.
• Maximum number of consecutive pages to program in the same “Transponder Write EEPROM Page”
request is three.
4.7 52h - Transponder Read EEPROM Page
CU Request :-
49 03 52 PN
CS
PN
:-
Page
Number
byte
(00-07)
SMARTRA Response :-
69 05
B0
B1
B2
B3
CS
B0 .. B3 :- Transponder bytes read (00-FF)
This request is only valid prior to key programming procedure with the Transponder in password mode.
Note :-
Note :-
SMARTRA will take up to 100ms to start sending the response bytes to the CU.