4.8 4Eh – Neutralise a [Learnt] Smartra
Message is instigated by Diagnostic Tester and passed to the Smartra through the EMS. The Smartra
will check if the DPN is correct before changing to [neutral] state.
CU Request :-
We request to place Smartra into Neutral Mode:
will check if the DPN is correct before changing to [neutral] state.
CU Request :-
We request to place Smartra into Neutral Mode:
49 0B 4E DPN1 DPN2 DPN3 DPN4 DPN5 DPN6 DPN7 DPN8 DPN9
C
S
DPN1..9
- Diagnostic PIN Number byte 1 to 9
SMARTRA Response :-
69
02
Return
CS
Return =
0x01 = Correct PIN changed from [Learnt] to [Neutral]
0x02 = Correct PIN already in Virgin State
0x03 = Correct PIN already in Neutral State
0x04
=
Diagnostic
PIN
incorrect
Note :-
-The EMS will pass this information to the Diagnostic Tester.
4.9 54h – Teach Smartra
Message is instigated by EMS when the Smartra State is [Virgin] or [Neutral] and if the Diagnostic Tester
wants to teach the Diagnostic PIN Number.
CU Request :-
wants to teach the Diagnostic PIN Number.
CU Request :-
49
0B
54
DPN1
DPN2
DPN3
DPN4
DPN5
DPN6
DPN7
DPN8
DPN9
CS
DPN1..9
- Diagnostic PIN Number byte 1 to 9
SMARTRA Response :-
69
02
Return
CS
Return
= 0x01 – Programmed Successfully
= 0x02 – Correct PIN (Smartra already in Learnt State).
= 0x03 – Incorrect PIN
= 0x02 – Correct PIN (Smartra already in Learnt State).
= 0x03 – Incorrect PIN
**Note**:
1) For backward compatibility the Smartra3 will by default function as a Smartra2 until the Teach Smartra
command is completed correctly.
2) When Smartra3 handles this message it shall convert the diagnostic PIN number to a secret KEY and
store it on the device.
1) For backward compatibility the Smartra3 will by default function as a Smartra2 until the Teach Smartra
command is completed correctly.
2) When Smartra3 handles this message it shall convert the diagnostic PIN number to a secret KEY and
store it on the device.