ADC Telecommunications Inc. DVLRCSSMR Benutzerhandbuch

Seite von 35
ADCP-75-134 • Issue A • April 2002 • Section 5: Maintenance
Page 5-17
©
 2002, ADC Telecommunications, Inc.
12. Place
 the HU On/Off switch in the ON position (press I). 
13. Verify
 that the fans run properly following power-up. 
14. Notify
 the NOC or alarm monitoring system operator that the system is going back online. 
5.4
Spectrum Transport Module Fan Replacement Procedure
The
 STM is equipped with a rear cooling fan that exhausts heated air from the STM enclosure.
Cool
 air enters the STM through vent openings on the side of the enclosure. Replacement of the
fan
 requires that the STM be turned off for a short period of time and that the STM be removed
from
 the cabinet. Use the following procedure to remove and replace the STM cooling fan. 
1. Before
 working on the STM or handling a fan, slip on an Electro-Static Discharge (ESD)
wrist
 strap and connect the ground wire to an earth ground source. Wear the ESD wrist
strap
 while completing each section of the fan installation procedure. 
2. Notify
 the NOC or alarm monitoring system operator that the system is going offline. 
3. Place
 the STM On/Off switch in the OFF position (press O). 
4. Disconnect
  the  various  power,  fiber  optic,  service,  alarm  wiring,  and  coaxial  cable
connectors
 from the STM front panel as specified in 
.
 
Figure 5-4. Spectrum Transport Module Cable Connections
Warning:
  Electronic  components  can  be damaged  by  static  electrical  discharge. To prevent
ESD
 damage, always wear an ESD wrist strap when working on the HU, STM, or LPA and
when
 handling electronic components. 
17617-A
Disconnect AC
power connector
Disconnect back-up battery
DC power connector
Disconnect alarm
connector
Disconnect power
monitor cable
connector
Disconnect TX, RX1, and
RX2 coaxial cable
connectors
1
2
3
4
5
6
7
Disconnect optical fiber
connectors. Place a dust
cap over each cable
connector and port adapter.
Disconnect service
connector (if present)