ADC Telecommunications Inc. DVLRCSSMR Benutzerhandbuch

Seite von 35
ADCP-75-134 • Issue A • April 2002 • Section 5: Maintenance
Page 5-20
©
 2002, ADC Telecommunications, Inc.
Figure 5-7. LPA Fan Removal and Replacement
6. Carefully
 withdraw the fan assembly from the LPA until the wiring harness is exposed and
the
 RJ-45 wiring harness connector is accessible. 
7. Disconnect
 the fan wiring harness connector from the LPA and lift the fan assembly away
from
 the LPA. 
8. Place
  a  small  amount  of  anti-corrosion  gel  on  the  connector  of  the  replacement  fan
assembly.
 
9. Orient
 the fan assembly so the air-flow arrow points into the LPA. 
10. Connect
 the fan assembly wiring harness connector to the LPA internal connector. 
11. Secure
 the fan assembly to the LPA using the four retainers removed in step 5. 
12. Replace
 the rear fan assembly using the same procedure covered in steps 5 through 11
except
 orient the rear fan so the air-flow arrow is pointing away from the LPA. 
13. When
 both fan assemblies have been replaced, re-install the LPA in the cabinet. 
14. Place
 the STM On/Off switch in the ON position (press I) and verify that both fans operate
properly.
 The front fan should draw air into the LPA and the rear fan should blow air out of
the
 LPA. 
15. Notify
 the NOC or alarm monitoring system operator that the system is going back online. 
16994-A
PULL ON RETAINERS 
TO REMOVE FAN