Nokia of America Corporation BBTRX-06 Benutzerhandbuch

Seite von 116
...................................................................................................................................................................................................
4
Ground the M6x10 grounding stud at Bias-Ts with customer provided grounding system.
Y-Bias-T connector
Route and connect RF jumper cables to the RRH
Use the following procedure to connect the RF jumper cables to the RF ports on top of
the RRH
...................................................................................................................................................................................................
1
Label both ends of each cable with receive diversity number.
...................................................................................................................................................................................................
2
Connect the RF jumper cable(s) to the RRH port(s) and route them from the RRH to the
RF antenna.
...................................................................................................................................................................................................
3
Providing adequate slack, cut each cable so it reaches its corresponding RF antenna
connector or, if applicable, its corresponding RF surge protector.
Re-mark each RF jumper cable if the cable marking has been removed.
...................................................................................................................................................................................................
4
Terminate the end of each cable with the supplied 7/16 DIN connector. (Use the
appropriate stripping tool. Refer to
for the appropriate tool required for installation).
M6 x 1.0 Grounding stud
M29 x 1.5-6g thread
Antenna port
DC Injection port
(40.0mm)
(20.0mm)
(31.8mm Hex flats)
(81.7mm)
BTS port
Mates to IEC 169-4: 169-1 or equivalent
(41.8mm)
Finish the installation
To route and connect RF jumper cables
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
FDD RRH 700L
3MN-00075-0002-RJZZA
Issue 0
September 2012
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
7-5
E
N D
O F
S T E P S
...................................................................................................................................................................................................