Nokia of America Corporation BBTRX-06 Benutzerhandbuch

Seite von 116
To finalize RRH installation
Initial start-up and system test procedures
The actual procedures for initial start-up and test are not covered in this document.
Before initial start-up and test
To perform initial start-up and system test, the RF jumper cables will be temporarily
disconnected at the RRH by the personnel who perform initial start-up and system test.
After performing initial start-up and system test, the personnel will permanently connect
the RF jumper cables to the RRH.
System test
Following installation of the RRH, the system should be tested before being put it into
operation. System test procedures are not covered in this installation document.
Information concerning system test and integration is contained in Alcatel-Lucent
Installation Engineering Handbook 401
.
Final actions after initial start-up and test
NOTICE
RF hazard!
If it is necessary to disconnect an RF jumper cable, make sure there is no transmit signal
in the RF jumper cable.
...................................................................................................................................................................................................
1
Once initial start-up and test have been completed, make sure the RF jumper cables are
properly connected to the RRH.
...................................................................................................................................................................................................
2
Torque each RF connector at the radio RRH to 25 Nm (221 in-lb).
Important! Hold the body of the connector (part connected to the entry cable) with a
22 mm open-end wrench. Torque the rotating nut with a 32 mm open-end wrench.
...................................................................................................................................................................................................
3
Secure the RF jumper cables along their route.
...................................................................................................................................................................................................
4
Inspect site for loose tools, materials, and parts. Remove all such loose tools, materials,
and parts.
Finish the installation
To finalize RRH installation
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
FDD RRH 700L
3MN-00075-0002-RJZZA
Issue 0
September 2012
Alcatel-Lucent – Proprietary
Use pursuant to applicable agreements
7-7