E F Johnson Company 2425130 Benutzerhandbuch

Seite von 34
CONVENTIONAL MODE FEATURES
21
May 2002
Part No. 002-5100-100
on the keypad programming parameters is located in 
the following sections.
Figure 6   Keypad Programming Menu Flow-
chart
Zone Password
Each zone can be programmed so that the correct 
password must then be entered before system or 
channel parameters in that zone can be changed by 
keypad programming. A different password can be 
programmed for each zone. 
When an attempt is made to select a system or 
channel parameter in a password protected zone, 
“ENTER PSWD” is displayed. The password is 
always eight digits long and is entered using the same 
procedure as used for the power-up password 
described on page 9. After the password is entered, 
system and channel parameters for that zone can be 
reprogrammed normally.
Zone Change Parameter
The “CHG ZONE” menu parameter selects the 
zone containing the conventional channel to be repro-
grammed. It does not change the zone selected for 
normal operation. 
Press the F2 key to select the “ZONE CHG” 
parameter and then scroll through the programmed 
zones by pressing the Up/Down switch. When the 
desired zone is displayed, select it by pressing the F2 
key.
Channel Change Parameter
The “CHNG CHAN” menu parameter selects the 
conventional channel to be reprogrammed. Disabled or 
SMARTNET/SmartZone channels cannot be selected. 
This does not change the channel selected for normal 
operation. 
Press the F2 key to select the “CHNG CHAN” 
parameter and then scroll through the programmed 
channels by pressing the Up/Down switch. When the 
desired channel is displayed, select it by pressing F2 
key.
System Parameters
NOTE: If “ENTER PSWD” is briefly displayed when 
attempting to select a parameter, see Zone Password 
description on page 21.
The “SYS PARMS” menu parameter selects the 
conventional mode timers to be reprogrammed (see 
following). Press the F2 key to select the “SYS 
PARMS” parameter and then press the Up/Down 
switch to display the desired parameter. Then press the 
F2 key again to select it.
SCAN TIMER - Selects the Scan Hold timer. Press the 
Up/Down switch to decrement/increment the timer in 
0.5-second steps, or set it to 0 seconds to disable it. 
When the desired value is displayed, store it by 
pressing the F2 key.
TX TIMER - Selects the transmit time-out timer. Press 
the Up/Down switch to decrement/increment the timer 
in 15-second steps, or disable it by selecting 0 
seconds. When the desired value is displayed, store it 
by pressing the F2 key.
PEN TIMER - Selects the penalty timer. Press the Up/
Down switch to decrement/increment the timer in 15-
second steps. When the desired value is displayed, 
store it by pressing the F2 key.
Zone
Channel
Change
Change
System 
Parameters
Channel
Parameters
Select
Zone
Select
Channel
Scan Hold Timer
Tx Timer
Penalty Timer
Conver. Timer
Rx Freq
Tx Freq
Rx Code/NAC
Tx Code/NAC
Tx Power
Tx Tmr On-Off
Squelch Adj
Chan Spacing
F1 = Select
F2 = Exit/Back
Up/Down = Scroll
Tlk Grp Sel