E F Johnson Company 2425130 Benutzerhandbuch

Seite von 34
23
May 2002
Part No. 002-5100-100
SMARTNET/SMARTZONE FEATURES
SMARTNET/SMARTZONE FEATURES
Introduction
An overview of the SMARTNET/SmartZone 
operating mode is located on page 10. The following 
information describes the features unique to the 
SMARTNET and SmartZone modes of operation. 
Refer to the “Radio-Wide Features” section starting on 
page 11 for information on features common to all 
operating modes. Conventional mode features are 
described in the preceding “Conventional Features” 
section.
Viewing Unit ID
When power is turned on with a SMARTNET/
SmartZone channel selected, the six-digit Unit ID is 
briefly displayed as IDxxxxxx. 
Placing and Receiving Standard Group Calls
Standard calls are between you and another 
mobile, group of mobiles, or a control station (a radio 
in a fixed location). Most calls are probably this type. 
Proceed as follows to place and receive these calls. 
Placing a Standard Group Call
1. Turn power on and set the volume as described on 
page 8. Select the zone and channel programmed for 
the talk group you want to call (see page 9). 
2. If encryption is used it may be automatically 
selected. If not, select the Secure mode if desired by 
by pressing the Clear/Secure option key or selecting 
that menu parameter. The encryption status cannot 
be changed if encryption is fixed on the talk group. 
Refer to page 10 for more information on secure 
communication.
3. Press the PTT switch and begin talking. A talk 
permit tone may sound to indicate when talking can 
begin. Events that may occur are as follows:
If in the secure mode and your transceiver is not 
programmed with the proper encryption key, 
“KEYFAIL” is displayed and the call must be 
made in the clear mode or the proper key must be 
programmed.
If the busy tone sounds and “BUSY” is displayed, 
the system is busy. Release the PTT switch and 
wait for the call back tone to sound. Then press 
the PTT switch within 3 seconds.
If a continuous tone sounds and “NO SYS” is 
displayed, you may be out-of-range. Drive closer 
or away from shielding objects and try again.
If your unit ID is invalid, the call is being made to 
an invalid group ID, group calls are not enabled, 
or the selected talk group is not programmed for 
the selected secure mode, “DISABLED ID” is 
displayed and an alert tone sounds.
If an attempt is made to change an analog call 
from the clear to secure mode and there is no 
available secure channel, “NO SEC” is flashed 
and the call continues in the clear mode.
If an attempt is made to change an analog channel 
from the secure to clear mode, “SEC ONLY” is 
displayed and the call continues in the secure 
mode. (Calls on digital channels can be changed 
if not strapped.)
If the secure mode is selected by the Secure/Clear 
option key or menu parameter and an attempt is 
made to transmit on a channel strapped as clear, 
“Clear Only” is displayed and the transmitter is 
disabled. Conversely, if the clear mode is selected 
and the channel is strapped as secure, “Secure 
Only” is displayed and the transmitter is disabled.
Receiving a Standard Group Call
When a SMARTNET/SmartZone group call is 
received, the transceiver can be programmed to 
display the Individual ID of the calling mobile and/or 
the received talk group alias. The Individual ID is 
briefly displayed when the call is received and the talk 
group and channel alias are then alternately displayed 
(if applicable).