Troubleshooting 
Page 38 of 41 
9.  Troubleshooting 
Use the following table to identify and correct common issues encountered when using the reader.  
Symptom 
Possible Causes 
Recommended Actions 
The LEDs do not come on 
during power up. 
There is no power to the reader. 
Verify the reader is connected to a USB 
2.0 or USB 3.1 host port and/or external 
power supply. 
The reader is damaged. 
Follow the procedure outlined in 
“Returning the reader for maintenance”. 
The power switch is in the Off 
position. 
Turn the reader on. 
The Red cross is flashing or 
permanently on. 
The reader has failed self-test or is 
damaged. 
Disconnect all cables and turn off. Plug in 
the PSU cable and turn on. Once 
successfully powered up then connect the 
USB cable. If this procedure does not 
clear the error then follow the procedure 
outlined in “Returning the reader for 
maintenance”. 
Green tick flashing 
USB cable is not connected 
Check USB cable is connected at both 
ends. Check USB cable is not damaged. 
Check PC USB port is not damaged or 
disabled. 
The reader is not 
communicating with host PC 
system. 
The cable is not properly 
connected or USB drivers are not 
properly installed. 
Verify that the USB cable is connected to 
the host. 
 
Verify that the USB driver is installed. 
 
Verify that only one reader is connected to 
the host system and only one instance of 
the host application is running. 
The Red cross LED 
illuminates when a document 
is scanned 
The document is non-machine 
readable. 
This is a normal condition when there is 
no machine readable data and only the 
image is captured from the document. 
The document is poorly printed or 
does not conform to specification.  
The reader is designed to read documents 
that are poorly printed. However, some 
documents are of such poor quality that 
the reader will not be able to process the 
OCR data. 
 
Verify the document conforms to ICAO 
9303 or OCR B font requirements 
High ambient light. 
Ensure that ambient light compensation is 
enabled in the software SDK 
 
Re-orient the reader so that bright light 
does not fall directly on the document 
window. 
The unit is not configured to read 
the document being scanned. 
Verify the reader configuration with 
technical staff. 
 
Contact Global Technical Services (GTS).