3.1 Background – Tamper Types
Many Invenco products support two types of tamper protection; in increasing order of security they are:
• removal tamper
• destructive tamper, also known as “Destructive Secure Reset” (DSR).
3.1.1 Tamper Indications
A DSR is a dramatic response to what a unit interprets as an integrity violation: the device shuts down
instantly, wiping its security keys and other sensitive information. The device is not ruined but it is
“bricked”: it cannot operate in any capacity and can be disassembled, repaired and reinitialized only
by Invenco – a return-to-base procedure. Returning a destructive-tampered unit to Invenco requires an
auditable process with formal changes of custody, probably including packaging, transport and staging.
The G7SDC will display a “DT event” screen; the G7UPC will display a fast (twice a second) red keypad
LED indication:
Fig. 3.1:
SDC Destructive Tamper (DT) event screen
In contrast, the removal tamper response is intentionally less drastic. Removal tamper sensors protect
a unit that is intact: it may have been removed – even maliciously – from a system in which it was
integrated, but the unit’s integrity has not been violated and it is still operational (albeit in a restricted
mode). Significantly its cryptographic keys have not been erased, although it remains incapable of
financial transactions until restored to normal operation from the removal-tampered state. If necessary
the unit can still perform a DSR.
DWI-00175 S1 R15
13